Changes for page BMS Main 3X
Last modified by Admin on 2025/02/18 14:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,51 +31,6 @@ 1 -(% class="box infomessage" %) 2 -((( 3 -BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 -))) 5 - 6 -= v3.2.1 = 7 - 8 -[[BMS_Main_3X_v3.2.1.bin>>FileManager.BMS_Main_3X_v3\.2\.1\.bin]] 9 - 10 -== Improvements == 11 - 12 -* new parameter that sets the delay before measuring the current to determine that precharge is finished (see the "Control - Precharge" section) 13 -* ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) 14 -* new flags indicating the readiness of battery modules to join for charging and discharging (see the "Modules" section) 15 -* new flag to set the "Voltage unbalance" errors for battery modules that are not ready to charge or discharge (see the "Protections - Voltage unbalance (in any state)" section) 16 -* Unibat: new parameters setting the BMS and VCU addresses (see the "External equipment - Unibat vehicle" section) 17 -* Unibat: new flag to invert the discharge current limit sent to the vehicle (see the "External equipment - Unibat vehicle" section) 18 -* Unibat: using the difference between the maximum and minimum temperatures among all cells as an input for the coolant pump controller 19 -* Unibat: automatically switch from discharging to charging mode if the CHARGE_ON signal or the charging station command is set (without rejoining the battery) 20 -* extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.) 21 - 22 -== Fixes == 23 - 24 -* resolving the issue of ignoring the minimum number of battery modules allowed to join located in the "Control - Discharge" section 25 -* resolving the issue of joining battery modules the number of which must be greater than or equal to the minimum value specified in the settings 26 -* making the service reset function work properly 27 -* small internal fixes 28 - 29 -= v3.2.0 = 30 - 31 31 (% class="wikigeneratedid" %) 32 - [[BMS_Main_3X_v3.2.0.bin>>FileManager.BMS_Main_3X_v3\.2\.0\.bin]]2 +BMS Main 3X firmware update procedure is described [[here>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%203/5.%20Firmware%20update/]]. 33 33 34 -== Features == 35 - 36 -* new algorithm in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithm is preferred in the battery systems with one contactor 37 -* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 38 -* new Max-Min algorithm for calculating the final battery SOC in the "Control - Calculation" section 39 -* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 40 -* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 41 - 42 -== Improvements == 43 - 44 -* ability to finish device initialization even if the number of battery modules found is less than the number of modules enabled 45 -* ability to configure and monitor the device via the CAN1 (ext) bus 46 -* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 47 -* Unibat: support for functional description v3.5 (protocol v1.5) 48 - 49 49 = v3.1.1 = 50 50 51 51 [[BMS_Main_3X_v3.1.1.bin>>FileManager.BMS_Main_3X_v3\.1\.1\.bin]]