Changes for page BMS Main 3X

Last modified by Admin on 2025/04/14 10:58

From version 9.1
edited by Admin
on 2025/02/18 14:58
Change comment: There is no comment for this version
To version 11.1
edited by Admin
on 2025/04/14 10:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,6 +3,39 @@
3 3  BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
4 4  )))
5 5  
6 += v3.2.4 =
7 +
8 +[[BMS_Main_3X_v3.2.4.bin>>FileManager.BMS_Main_3X_v3\.2\.4\.bin]]
9 +
10 +== Improvements ==
11 +
12 +* new flags that allow to interrupt (shorten) the module balancing stage if all battery modules are already joined (see the "Control - Charge", "Control - Discharge", "Control - Charge/Discharge" sections)
13 +* forwarding CLI and bootloader CAN messages from CAN1 interface to CAN2 interface and back, that allows the user to configure and update the firmware of internal devices such as BMS IMD or BMS Display
14 +* new parameter for setting the type of network to which the BMS GSM communication module connects (see the "Connectivity - Cellular" section)
15 +
16 +== Fixes ==
17 +
18 +* Unibat: resolving the problem of calculating the CRC of the HVESSS1 message
19 +* Unibat: resolving the problem of sending a message about battery disconnection even it is already disconnected
20 +
21 += v3.2.3 =
22 +
23 +[[BMS_Main_3X_v3.2.3.bin>>FileManager.BMS_Main_3X_v3\.2\.3\.bin]]
24 +
25 +== Improvements ==
26 +
27 +* forwarding CLI and bootloader CAN messages from CAN1 and CAN2 interfaces to CAN3 interface and back, that allows the user to configure and update the firmware of battery modules without direct connection to the modules
28 +* ability to acknowledge errors in the error journal via the Modbus protocol (holding registers 0x4100-0x4101)
29 +* ability to update the device serial number from the service account if the number is reset to the default value for some reason (see the "Service" section)
30 +* new flag that controls whether to use open circuit voltage or actual voltage when determining the voltage unbalance error (see the "Protections - Voltage unbalance (in any state)" section)
31 +* new regulator that maintains battery current limiting to ensure that actual module currents do not exceed their current limits (see the "Control - Charge", "Control - Discharge", "Control - Charge/Discharge" sections)
32 +* ability to select the battery module errors that cause the battery critical error (see the "Protections - Critical error" section)
33 +* Unibat: refined algorithms and new parameters to meet requirements of version 7 of the logic
34 +
35 +== Fixes ==
36 +
37 +* resolving the problem of saving discrete input signals of battery modules in log files
38 +
6 6  = v3.2.1 =
7 7  