Changes for page BMS Main 3X
Last modified by Admin on 2025/02/18 14:58
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Tags
-
... ... @@ -1,1 +1,0 @@ 1 -BMS Main 3X - Content
-
... ... @@ -1,32 +1,7 @@ 1 -(% class="box infomessage" %) 2 -((( 3 -BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 -))) 1 += 3.1.1 = 5 5 6 - = v3.2.0 =3 +... 7 7 8 -(% class="wikigeneratedid" %) 9 -[[BMS_Main_3X_v3.2.0.bin>>FileManager.BMS_Main_3X_v3\.2\.0\.bin]] 10 - 11 -== Features == 12 - 13 -* new algorithm in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithm is preferred in the battery systems with one contactor 14 -* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 15 -* new Max-Min algorithm for calculating the final battery SOC in the "Control - Calculation" section 16 -* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 17 -* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 18 - 19 -== Improvements == 20 - 21 -* ability to finish device initialization even if the number of battery modules found is less than the number of modules enabled 22 -* ability to configure and monitor the device via the CAN1 (ext) bus 23 -* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 24 -* Unibat: support for functional description v3.5 (protocol v1.5) 25 - 26 -= v3.1.1 = 27 - 28 -[[BMS_Main_3X_v3.1.1.bin>>FileManager.BMS_Main_3X_v3\.1\.1\.bin]] 29 - 30 30 == Fixes == 31 31 32 32 * resolving the problem of incorrect range of temperature parameter values (in the "Control - Coolant pump" section) ... ... @@ -34,11 +34,11 @@ 34 34 * resolving the problem of writing the device's working time to a non-volatile memory very often 35 35 * resolving the issue of preparing battery module states written to Modbus registers 36 36 37 - = v3.1.0=12 +3.1.0 38 38 39 - [[BMS_Main_3X_v3.1.0.bin>>FileManager.BMS_Main_3X_v3\.1\.0\.bin]]14 +... 40 40 41 - ==Features==16 +Features 42 42 43 43 * new parameter to set the minimum number of battery modules allowed to join (see the "Control - Charge" and "Control - Discharge" sections) 44 44 * ability to rejoin battery modules if their voltage is close to the battery voltage (see the "Control - Charge" and "Control - Discharge" sections) ... ... @@ -46,12 +46,8 @@ 46 46 * new internal signal "General error (modules)" which is the logical sum of the "General error" signals from the battery modules 47 47 * new assignments "Critical error" and "General error (modules)" for the discrete outputs and power switches (see the "Signals - Output discrete signals - Assignments" and "Signals - Power switches - Assignments" sections) 48 48 49 - ==Improvements==24 +Improvements 50 50 51 -* use the measured voltage before contactors as the battery voltage if the "Control - High voltage" function is enabled 52 -* Unibat: new flag to enable sending a control message to start/stop ventilation fans installed in the battery modules (see the "External equipment - Unibat vehicle" section) 53 -* rearrangements in the settings sections, which are made to simplify the setup process 54 - 55 -== Fixes == 56 - 57 -* Unibat: minor changes in the communication protocol 26 +- use the measured voltage before contactors as the battery voltage if the "Control - High voltage" function is enabled 27 +- Unibat: new flag to enable sending a control message to start/stop ventilation fans installed in the battery modules (see the "External equipment - Unibat vehicle" section) 28 +- rearrangements in the settings sections, which are made to simplify the setup process