Changes for page BMS Main 3X
Last modified by Admin on 2025/02/18 14:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,33 @@ 1 -(% class="wikigeneratedid" %) 2 -BMS Main 3X firmware update procedure is described [[here>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%203/5.%20Firmware%20update/]]. 1 +(% class="box infomessage" %) 2 +((( 3 +BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 +))) 3 3 4 -(% class="wikigeneratedid" %) 5 -v3.2.0 6 += v3.2.1 = 6 6 8 +[[BMS_Main_3X_v3.2.1.bin>>FileManager.BMS_Main_3X_v3\.2\.1\.bin]] 9 + 10 +== Improvements == 11 + 12 +* new parameter that sets the delay before measuring the current to determine that precharge is finished (see the "Control - Precharge" section) 13 +* ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) 14 +* new flags indicating the readiness of battery modules to join for charging and discharging (see the "Modules" section) 15 +* new flag to set the "Voltage unbalance" errors for battery modules that are not ready to charge or discharge (see the "Protections - Voltage unbalance (in any state)" section) 16 +* Unibat: new parameters setting the BMS and VCU addresses (see the "External equipment - Unibat vehicle" section) 17 +* Unibat: new flag to invert the discharge current limit sent to the vehicle (see the "External equipment - Unibat vehicle" section) 18 +* Unibat: using the difference between the maximum and minimum temperatures among all cells as an input for the coolant pump controller 19 +* Unibat: automatically switch from discharging to charging mode if the CHARGE_ON signal or the charging station command is set (without rejoining the battery) 20 +* extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.) 21 + 22 +== Fixes == 23 + 24 +* resolving the issue of ignoring the minimum number of battery modules allowed to join located in the "Control - Discharge" section 25 +* resolving the issue of joining battery modules the number of which must be greater than or equal to the minimum value specified in the settings 26 +* making the service reset function work properly 27 +* small internal fixes 28 + 29 += v3.2.0 = 30 + 7 7 (% class="wikigeneratedid" %) 8 8 [[BMS_Main_3X_v3.2.0.bin>>FileManager.BMS_Main_3X_v3\.2\.0\.bin]] 9 9