Changes for page BMS Main 3X

Last modified by Admin on 2026/02/18 13:39

From version 23.1
edited by Admin
on 2026/02/18 13:39
Change comment: There is no comment for this version
To version 21.2
edited by Admin
on 2026/02/05 03:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,35 +3,22 @@
3 3  BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]].
4 4  )))
5 5  
6 -= v3.8.2 =
7 -
8 -[[BMS_Main_3X_v3.8.2.bin>>FileManager.BMS_Main_3X_v3\.8\.2\.bin]]
9 -
10 -== Improvements ==
11 -
12 -* Unibat: preventing the reset of the HVBPITS and HVBPITR signals if the device shutdown was caused by the insulation fault
13 -
14 -== Fixes ==
15 -
16 -* Unibat: charge current limit protection is disabled in charge mode only when the "Use continuous charge current limit" flag is set
17 -* Unibat: discharge current limit protection is enabled regardless of whether the battery is in discharge or charge mode
18 -
19 19  = v3.8.1 =
20 20  
21 21  [[BMS_Main_3X_v3.8.1.bin>>FileManager.BMS_Main_3X_v3\.8\.1\.bin]]
22 22  
23 -== Improvements ==
10 +Improvements
24 24  
25 -* setting and clearing the "Voltage unbalance" errors without delays
26 -* new CAN bus speed is not applied until the device is rebooted
27 -* logging the following new parameters: "UnibatState", "UnibatOperationalModeState", "Keyrun", "ChargeOn"
28 -* Unibat: ability to shutdown the battery if its SOC is too low (see the "External equipment - Unibat vehicle - Diagnostic parameters" section)
29 -* Unibat: change the resolution of parameters CC and DC from 0.01 to 0.1 Ah/bit
30 -* Unibat: do not turn on the amber lamp if the actual battery SOC is equal to the configured maximum operational SOC
12 +setting and clearing the "Voltage unbalance" errors without delays
13 +{new CAN bus speed is not applied until the device is rebooted
14 +- logging the following new parameters: "UnibatState", "UnibatOperationalModeState", "Keyrun", "ChargeOn"
15 +- Unibat: ability to shutdown the battery if its SOC is too low (see the "External equipment - Unibat vehicle - Diagnostic parameters" section)
16 +- Unibat: change the resolution of parameters CC and DC from 0.01 to 0.1 Ah/bit
17 +- Unibat: do not turn on the amber lamp if the actual battery SOC is equal to the configured maximum operational SOC
31 31  
32 -== Fixes ==
19 +Fixes
33 33  
34 -* resolving the problem of completing the initialization process before the power switch voltage stabilizes
21 +- resolving the problem of completing the initialization process before the power switch voltage stabilizes
35 35  
36 36  = v3.8.0 =
37 37