Changes for page BMS Main 3X
Last modified by Admin on 2026/02/18 13:39
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,127 +1,8 @@ 1 1 (% class="box infomessage" %) 2 2 ((( 3 -BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3. 6\. Firmware update.WebHome]].3 +BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 -= v3.8.2 = 7 - 8 -[[BMS_Main_3X_v3.8.2.bin>>FileManager.BMS_Main_3X_v3\.8\.2\.bin]] 9 - 10 -== Improvements == 11 - 12 -* Unibat: preventing the reset of the HVBPITS and HVBPITR signals if the device shutdown was caused by the insulation fault 13 - 14 -== Fixes == 15 - 16 -* Unibat: charge current limit protection is disabled in charge mode only when the "Use continuous charge current limit" flag is set 17 -* Unibat: discharge current limit protection is enabled regardless of whether the battery is in discharge or charge mode 18 - 19 -= v3.8.1 = 20 - 21 -[[BMS_Main_3X_v3.8.1.bin>>FileManager.BMS_Main_3X_v3\.8\.1\.bin]] 22 - 23 -== Improvements == 24 - 25 -* setting and clearing the "Voltage unbalance" errors without delays 26 -* new CAN bus speed is not applied until the device is rebooted 27 -* logging the following new parameters: "UnibatState", "UnibatOperationalModeState", "Keyrun", "ChargeOn" 28 -* Unibat: ability to shutdown the battery if its SOC is too low (see the "External equipment - Unibat vehicle - Diagnostic parameters" section) 29 -* Unibat: change the resolution of parameters CC and DC from 0.01 to 0.1 Ah/bit 30 -* Unibat: do not turn on the amber lamp if the actual battery SOC is equal to the configured maximum operational SOC 31 - 32 -== Fixes == 33 - 34 -* resolving the problem of completing the initialization process before the power switch voltage stabilizes 35 - 36 -= v3.8.0 = 37 - 38 -[[BMS_Main_3X_v3.8.0.bin>>FileManager.BMS_Main_3X_v3\.8\.0\.bin]] 39 - 40 -== Features == 41 - 42 -* support for the Trolleybat vehicle (see the "External equipment - Trolleybat vehicle" section) 43 - 44 -== Improvements == 45 - 46 -* checking the continuous charge current limit only if the "Use continuous charge current limit" flag is set in the "External equipment - Unibat vehicle - General parameters" section 47 -* Unibat: transition to charging mode according to the condition EESCD=7 48 - 49 -== Fixes == 50 - 51 -* resolving the problem of completing the initialization process before the power switch voltage stabilizes 52 -* Unibat: prevent the "Charge request" and "Discharge request" signals from being reset if the Unibat vehicle goes offline (the signals are controlled in the Unibat state machine) 53 - 54 -= v3.7.1 = 55 - 56 -[[BMS_Main_3X_v3.7.1.bin>>FileManager.BMS_Main_3X_v3\.7\.1\.bin]] 57 - 58 -== Fixes == 59 - 60 -* Unibat: do not send the insulation error DTC if the IMD goes offline when the battery system is in the shutdown mode 61 - 62 -= v3.7.0 = 63 - 64 -[[BMS_Main_3X_v3.7.0.bin>>FileManager.BMS_Main_3X_v3\.7\.0\.bin]] 65 - 66 -== Features == 67 - 68 -* new profile section with global battery status, which includes total charge and energy counters, total operating time, contactor opening count, etc. (see the "Profile" tab in the Unified monitor) 69 -* new total charge counters (plus and minus) 70 - 71 -== Improvements == 72 - 73 -* Unibat: new flag to set the custom value (=3) for the EESCD signal (see the "External equipment - Unibat vehicle - General parameters" section) 74 -* Unibat: new bit field to ignore internal errors that cause battery shutdown (see the "External equipment - Unibat vehicle - General parameters" section) 75 -* Unibat: sending a new packet containing the continuous charge current limit 76 - 77 -== Fixes == 78 - 79 -* optimization of the logging process, minimizing the time to open the next log file if the current one is full 80 -* resolving the stability problem when the SD card is full 81 -* Unibat: prevent sending module online statuses if the power down condition is met 82 -* Unibat: small fixes 83 - 84 -= v3.6.2 = 85 - 86 -[[BMS_Main_3X_v3.6.2.bin>>FileManager.BMS_Main_3X_v3\.6\.2\.bin]] 87 - 88 -== Improvements == 89 - 90 -* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V 91 -* Unibat: new flag that allows to hide the insulation testing status when repeating measurements (see the "External equipment - Unibat vehicle" section) 92 -* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all CAN3 (BMS) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address 93 - 94 -== Fixes == 95 - 96 -* resolving the issue of false warnings indicating that the battery current exceeds the current limits (affects Unibat vehicle) 97 -* Unibat: changes that make it so that the output period is responsible for only 4 messages, not for all messages (see the "External equipment - Unibat vehicle" section) 98 -* Unibat: resolving the issue of TP messages not being sent if the transport is already transmitting something at the time of the request 99 -* corrections of typos in parameter descriptions 100 - 101 -= v3.6.1 = 102 - 103 -[[BMS_Main_3X_v3.6.1.bin>>FileManager.BMS_Main_3X_v3\.6\.1\.bin]] 104 - 105 -== Improvements == 106 - 107 -* new parameters for switching to the sum of battery modules' currents if the current sensor error is detected or the sensor is saturated (see the "Inputs - Current sensor" section) 108 -* new flag allowing to swap CAN2 (int) and CAN3 (BMS) interfaces (see the "Connectivity" section under the service account) 109 - 110 -= v3.6.0 = 111 - 112 -[[BMS_Main_3X_v3.6.0.bin>>FileManager.BMS_Main_3X_v3\.6\.0\.bin]] 113 - 114 -== Features == 115 - 116 -* Unibat: refined algorithms and new parameters to meet requirements of version 8.5 of the logic (protocol v6.1) 117 - 118 -== Improvements == 119 - 120 -* new flag enabling fast current measurements (see the "Signals - Current sensor" section) 121 -* new parameters to ignore the specified errors when setting the critical error (see the "Protections - Critical error" section) 122 -* displaying HV calibration values for the service account (see the "Service - Calibration" section) 123 -* Unibat: structuring parameters into subgroups: "General parameters", "Battery parameters", "Diagnostic parameters", "Power limiting parameters", "Battery version" (see the "External equipment - Unibat vehicle" section) 124 - 125 125 = v3.5.0 = 126 126 127 127 [[BMS_Main_3X_v3.5.0.bin>>FileManager.BMS_Main_3X_v3\.5\.0\.bin]]