Changes for page BMS Main 3X
Last modified by Admin on 2026/02/18 13:39
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,6 +3,19 @@ 3 3 BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v3.8.2 = 7 + 8 +[[BMS_Main_3X_v3.8.2.bin>>FileManager.BMS_Main_3X_v3\.8\.2\.bin]] 9 + 10 +== Improvements == 11 + 12 +* Unibat: preventing the reset of the HVBPITS and HVBPITR signals if the device shutdown was caused by the insulation fault 13 + 14 +== Fixes == 15 + 16 +* Unibat: charge current limit protection is disabled in charge mode only when the "Use continuous charge current limit" flag is set 17 +* Unibat: discharge current limit protection is enabled regardless of whether the battery is in discharge or charge mode 18 + 6 6 = v3.8.1 = 7 7 8 8 [[BMS_Main_3X_v3.8.1.bin>>FileManager.BMS_Main_3X_v3\.8\.1\.bin]]