... ... @@ -3,23 +3,6 @@
3 3  BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]].
4 4  )))
5 5  
6 -= v3.8.1 =
7 -
8 -[[BMS_Main_3X_v3.8.1.bin>>FileManager.BMS_Main_3X_v3\.8\.1\.bin]]
9 -
10 -== Improvements ==
11 -
12 -* setting and clearing the "Voltage unbalance" errors without delays
13 -* new CAN bus speed is not applied until the device is rebooted
14 -* logging the following new parameters: "UnibatState", "UnibatOperationalModeState", "Keyrun", "ChargeOn"
15 -* Unibat: ability to shutdown the battery if its SOC is too low (see the "External equipment - Unibat vehicle - Diagnostic parameters" section)
16 -* Unibat: change the resolution of parameters CC and DC from 0.01 to 0.1 Ah/bit
17 -* Unibat: do not turn on the amber lamp if the actual battery SOC is equal to the configured maximum operational SOC
18 -
19 -== Fixes ==
20 -
21 -* resolving the problem of completing the initialization process before the power switch voltage stabilizes
22 -
23 23  = v3.8.0 =
24 24  