Changes for page BMS Main 3X
Last modified by Admin on 2026/01/20 11:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,82 +1,8 @@ 1 1 (% class="box infomessage" %) 2 2 ((( 3 -BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3. 6\. Firmware update.WebHome]].3 +BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 -= v3.8.0 = 7 - 8 -[[BMS_Main_3X_v3.8.0.bin>>FileManager.BMS_Main_3X_v3\.8\.0\.bin]] 9 - 10 -== Features == 11 - 12 -* support for the Trolleybat vehicle (see the "External equipment - Trolleybat vehicle" section) 13 - 14 -== Improvements == 15 - 16 -* checking the continuous charge current limit only if the "Use continuous charge current limit" flag is set in the "External equipment - Unibat vehicle - General parameters" section 17 -* Unibat: transition to charging mode according to the condition EESCD=7 18 - 19 -== Fixes == 20 - 21 -* resolving the problem of completing the initialization process before the power switch voltage stabilizes 22 -* Unibat: prevent the "Charge request" and "Discharge request" signals from being reset if the Unibat vehicle goes offline (the signals are controlled in the Unibat state machine) 23 - 24 -= v3.7.1 = 25 - 26 -[[BMS_Main_3X_v3.7.1.bin>>FileManager.BMS_Main_3X_v3\.7\.1\.bin]] 27 - 28 -== Fixes == 29 - 30 -* Unibat: do not send the insulation error DTC if the IMD goes offline when the battery system is in the shutdown mode 31 - 32 -= v3.7.0 = 33 - 34 -[[BMS_Main_3X_v3.7.0.bin>>FileManager.BMS_Main_3X_v3\.7\.0\.bin]] 35 - 36 -== Features == 37 - 38 -* new profile section with global battery status, which includes total charge and energy counters, total operating time, contactor opening count, etc. (see the "Profile" tab in the Unified monitor) 39 -* new total charge counters (plus and minus) 40 - 41 -== Improvements == 42 - 43 -* Unibat: new flag to set the custom value (=3) for the EESCD signal (see the "External equipment - Unibat vehicle - General parameters" section) 44 -* Unibat: new bit field to ignore internal errors that cause battery shutdown (see the "External equipment - Unibat vehicle - General parameters" section) 45 -* Unibat: sending a new packet containing the continuous charge current limit 46 - 47 -== Fixes == 48 - 49 -* optimization of the logging process, minimizing the time to open the next log file if the current one is full 50 -* resolving the stability problem when the SD card is full 51 -* Unibat: prevent sending module online statuses if the power down condition is met 52 -* Unibat: small fixes 53 - 54 -= v3.6.2 = 55 - 56 -[[BMS_Main_3X_v3.6.2.bin>>FileManager.BMS_Main_3X_v3\.6\.2\.bin]] 57 - 58 -== Improvements == 59 - 60 -* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V 61 -* Unibat: new flag that allows to hide the insulation testing status when repeating measurements (see the "External equipment - Unibat vehicle" section) 62 -* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all CAN3 (BMS) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address 63 - 64 -== Fixes == 65 - 66 -* resolving the issue of false warnings indicating that the battery current exceeds the current limits (affects Unibat vehicle) 67 -* Unibat: changes that make it so that the output period is responsible for only 4 messages, not for all messages (see the "External equipment - Unibat vehicle" section) 68 -* Unibat: resolving the issue of TP messages not being sent if the transport is already transmitting something at the time of the request 69 -* corrections of typos in parameter descriptions 70 - 71 -= v3.6.1 = 72 - 73 -[[BMS_Main_3X_v3.6.1.bin>>FileManager.BMS_Main_3X_v3\.6\.1\.bin]] 74 - 75 -== Improvements == 76 - 77 -* new parameters for switching to the sum of battery modules' currents if the current sensor error is detected or the sensor is saturated (see the "Inputs - Current sensor" section) 78 -* new flag allowing to swap CAN2 (int) and CAN3 (BMS) interfaces (see the "Connectivity" section under the service account) 79 - 80 80 = v3.6.0 = 81 81 82 82 [[BMS_Main_3X_v3.6.0.bin>>FileManager.BMS_Main_3X_v3\.6\.0\.bin]]