Changes for page BMS Main 3X
Last modified by Admin on 2026/02/18 13:39
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,6 +3,54 @@ 3 3 BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v3.8.2 = 7 + 8 +[[BMS_Main_3X_v3.8.2.bin>>FileManager.BMS_Main_3X_v3\.8\.2\.bin]] 9 + 10 +== Improvements == 11 + 12 +* Unibat: preventing the reset of the HVBPITS and HVBPITR signals if the device shutdown was caused by the insulation fault 13 + 14 +== Fixes == 15 + 16 +* Unibat: charge current limit protection is disabled in charge mode only when the "Use continuous charge current limit" flag is set 17 +* Unibat: discharge current limit protection is enabled regardless of whether the battery is in discharge or charge mode 18 + 19 += v3.8.1 = 20 + 21 +[[BMS_Main_3X_v3.8.1.bin>>FileManager.BMS_Main_3X_v3\.8\.1\.bin]] 22 + 23 +== Improvements == 24 + 25 +* setting and clearing the "Voltage unbalance" errors without delays 26 +* new CAN bus speed is not applied until the device is rebooted 27 +* logging the following new parameters: "UnibatState", "UnibatOperationalModeState", "Keyrun", "ChargeOn" 28 +* Unibat: ability to shutdown the battery if its SOC is too low (see the "External equipment - Unibat vehicle - Diagnostic parameters" section) 29 +* Unibat: change the resolution of parameters CC and DC from 0.01 to 0.1 Ah/bit 30 +* Unibat: do not turn on the amber lamp if the actual battery SOC is equal to the configured maximum operational SOC 31 + 32 +== Fixes == 33 + 34 +* resolving the problem of completing the initialization process before the power switch voltage stabilizes 35 + 36 += v3.8.0 = 37 + 38 +[[BMS_Main_3X_v3.8.0.bin>>FileManager.BMS_Main_3X_v3\.8\.0\.bin]] 39 + 40 +== Features == 41 + 42 +* support for the Trolleybat vehicle (see the "External equipment - Trolleybat vehicle" section) 43 + 44 +== Improvements == 45 + 46 +* checking the continuous charge current limit only if the "Use continuous charge current limit" flag is set in the "External equipment - Unibat vehicle - General parameters" section 47 +* Unibat: transition to charging mode according to the condition EESCD=7 48 + 49 +== Fixes == 50 + 51 +* resolving the problem of completing the initialization process before the power switch voltage stabilizes 52 +* Unibat: prevent the "Charge request" and "Discharge request" signals from being reset if the Unibat vehicle goes offline (the signals are controlled in the Unibat state machine) 53 + 6 6 = v3.7.1 = 7 7 8 8 [[BMS_Main_3X_v3.7.1.bin>>FileManager.BMS_Main_3X_v3\.7\.1\.bin]]