... ... @@ -3,6 +3,54 @@
3 3  BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]].
4 4  )))
5 5  
6 += v3.8.2 =
7 +
8 +[[BMS_Main_3X_v3.8.2.bin>>FileManager.BMS_Main_3X_v3\.8\.2\.bin]]
9 +
10 +== Improvements ==
11 +
12 +* Unibat: preventing the reset of the HVBPITS and HVBPITR signals if the device shutdown was caused by the insulation fault
13 +
14 +== Fixes ==
15 +
16 +* Unibat: charge current limit protection is disabled in charge mode only when the "Use continuous charge current limit" flag is set
17 +* Unibat: discharge current limit protection is enabled regardless of whether the battery is in discharge or charge mode
18 +
19 += v3.8.1 =
20 +
21 +[[BMS_Main_3X_v3.8.1.bin>>FileManager.BMS_Main_3X_v3\.8\.1\.bin]]
22 +
23 +== Improvements ==
24 +
25 +* setting and clearing the "Voltage unbalance" errors without delays
26 +* new CAN bus speed is not applied until the device is rebooted
27 +* logging the following new parameters: "UnibatState", "UnibatOperationalModeState", "Keyrun", "ChargeOn"
28 +* Unibat: ability to shutdown the battery if its SOC is too low (see the "External equipment - Unibat vehicle - Diagnostic parameters" section)
29 +* Unibat: change the resolution of parameters CC and DC from 0.01 to 0.1 Ah/bit
30 +* Unibat: do not turn on the amber lamp if the actual battery SOC is equal to the configured maximum operational SOC
31 +
32 +== Fixes ==
33 +
34 +* resolving the problem of completing the initialization process before the power switch voltage stabilizes
35 +
36 += v3.8.0 =
37 +
38 +[[BMS_Main_3X_v3.8.0.bin>>FileManager.BMS_Main_3X_v3\.8\.0\.bin]]
39 +
40 +== Features ==
41 +
42 +* support for the Trolleybat vehicle (see the "External equipment - Trolleybat vehicle" section)
43 +
44 +== Improvements ==
45 +
46 +* checking the continuous charge current limit only if the "Use continuous charge current limit" flag is set in the "External equipment - Unibat vehicle - General parameters" section
47 +* Unibat: transition to charging mode according to the condition EESCD=7
48 +
49 +== Fixes ==
50 +
51 +* resolving the problem of completing the initialization process before the power switch voltage stabilizes
52 +* Unibat: prevent the "Charge request" and "Discharge request" signals from being reset if the Unibat vehicle goes offline (the signals are controlled in the Unibat state machine)
53 +
6 6  = v3.7.1 =
7 7  
8 8  [[BMS_Main_3X_v3.7.1.bin>>FileManager.BMS_Main_3X_v3\.7\.1\.bin]]