Changes for page BMS Main 3X
Last modified by Admin on 2025/12/10 16:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,55 +1,8 @@ 1 1 (% class="box infomessage" %) 2 2 ((( 3 -BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3. 6\. Firmware update.WebHome]].3 +BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 -= v3.7.1 = 7 - 8 -[[BMS_Main_3X_v3.7.1.bin>>FileManager.BMS_Main_3X_v3\.7\.1\.bin]] 9 - 10 -== Fixes == 11 - 12 -* Unibat: do not send the insulation error DTC if the IMD goes offline when the battery system is in the shutdown mode 13 - 14 -= v3.7.0 = 15 - 16 -[[BMS_Main_3X_v3.7.0.bin>>FileManager.BMS_Main_3X_v3\.7\.0\.bin]] 17 - 18 -== Features == 19 - 20 -* new profile section with global battery status, which includes total charge and energy counters, total operating time, contactor opening count, etc. (see the "Profile" tab in the Unified monitor) 21 -* new total charge counters (plus and minus) 22 - 23 -== Improvements == 24 - 25 -* Unibat: new flag to set the custom value (=3) for the EESCD signal (see the "External equipment - Unibat vehicle - General parameters" section) 26 -* Unibat: new bit field to ignore internal errors that cause battery shutdown (see the "External equipment - Unibat vehicle - General parameters" section) 27 -* Unibat: sending a new packet containing the continuous charge current limit 28 - 29 -== Fixes == 30 - 31 -* optimization of the logging process, minimizing the time to open the next log file if the current one is full 32 -* resolving the stability problem when the SD card is full 33 -* Unibat: prevent sending module online statuses if the power down condition is met 34 -* Unibat: small fixes 35 - 36 -= v3.6.2 = 37 - 38 -[[BMS_Main_3X_v3.6.2.bin>>FileManager.BMS_Main_3X_v3\.6\.2\.bin]] 39 - 40 -== Improvements == 41 - 42 -* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V 43 -* Unibat: new flag that allows to hide the insulation testing status when repeating measurements (see the "External equipment - Unibat vehicle" section) 44 -* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all CAN3 (BMS) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address 45 - 46 -== Fixes == 47 - 48 -* resolving the issue of false warnings indicating that the battery current exceeds the current limits (affects Unibat vehicle) 49 -* Unibat: changes that make it so that the output period is responsible for only 4 messages, not for all messages (see the "External equipment - Unibat vehicle" section) 50 -* Unibat: resolving the issue of TP messages not being sent if the transport is already transmitting something at the time of the request 51 -* corrections of typos in parameter descriptions 52 - 53 53 = v3.6.1 = 54 54 55 55 [[BMS_Main_3X_v3.6.1.bin>>FileManager.BMS_Main_3X_v3\.6\.1\.bin]]