Changes for page BMS Main 3X

Last modified by Admin on 2025/02/18 14:58

From version 2.1
edited by Admin
on 2024/11/18 10:24
Change comment: There is no comment for this version
To version 8.1
edited by Admin
on 2024/12/25 14:04
Change comment: There is no comment for this version

Summary

Details

Page properties
Tags
... ... @@ -1,0 +1,1 @@
1 +BMS Main 3X
Content
... ... @@ -1,7 +1,32 @@
1 -= 3.1.1 =
1 +(% class="box infomessage" %)
2 +(((
3 +BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
4 +)))
2 2  
3 -...
6 += v3.2.0 =
4 4  
8 +(% class="wikigeneratedid" %)
9 +[[BMS_Main_3X_v3.2.0.bin>>FileManager.BMS_Main_3X_v3\.2\.0\.bin]]
10 +
11 +== Features ==
12 +
13 +* new algorithm in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithm is preferred in the battery systems with one contactor
14 +* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section
15 +* new Max-Min algorithm for calculating the final battery SOC in the "Control - Calculation" section
16 +* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section)
17 +* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section)
18 +
19 +== Improvements ==
20 +
21 +* ability to finish device initialization even if the number of battery modules found is less than the number of modules enabled
22 +* ability to configure and monitor the device via the CAN1 (ext) bus
23 +* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section
24 +* Unibat: support for functional description v3.5 (protocol v1.5)
25 +
26 += v3.1.1 =
27 +
28 +[[BMS_Main_3X_v3.1.1.bin>>FileManager.BMS_Main_3X_v3\.1\.1\.bin]]
29 +
5 5  == Fixes ==
6 6  
7 7  * resolving the problem of incorrect range of temperature parameter values (in the "Control - Coolant pump" section)
... ... @@ -9,9 +9,9 @@
9 9  * resolving the problem of writing the device's working time to a non-volatile memory very often
10 10  * resolving the issue of preparing battery module states written to Modbus registers
11 11  
12 -= 3.1.0 =
37 += v3.1.0 =
13 13  
14 -...
39 +[[BMS_Main_3X_v3.1.0.bin>>FileManager.BMS_Main_3X_v3\.1\.0\.bin]]
15 15  
16 16  == Features ==
17 17