Changes for page BMS Main 3X
Last modified by Admin on 2026/02/18 13:39
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +1,51 @@ 1 1 (% class="box infomessage" %) 2 2 ((( 3 -BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3. 5\. Firmware update.WebHome]].3 +BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v3.8.1 = 7 + 8 +[[BMS_Main_3X_v3.8.1.bin>>FileManager.BMS_Main_3X_v3\.8\.1\.bin]] 9 + 10 +== Improvements == 11 + 12 +* setting and clearing the "Voltage unbalance" errors without delays 13 +* new CAN bus speed is not applied until the device is rebooted 14 +* logging the following new parameters: "UnibatState", "UnibatOperationalModeState", "Keyrun", "ChargeOn" 15 +* Unibat: ability to shutdown the battery if its SOC is too low (see the "External equipment - Unibat vehicle - Diagnostic parameters" section) 16 +* Unibat: change the resolution of parameters CC and DC from 0.01 to 0.1 Ah/bit 17 +* Unibat: do not turn on the amber lamp if the actual battery SOC is equal to the configured maximum operational SOC 18 + 19 +== Fixes == 20 + 21 +* resolving the problem of completing the initialization process before the power switch voltage stabilizes 22 + 23 += v3.8.0 = 24 + 25 +[[BMS_Main_3X_v3.8.0.bin>>FileManager.BMS_Main_3X_v3\.8\.0\.bin]] 26 + 27 +== Features == 28 + 29 +* support for the Trolleybat vehicle (see the "External equipment - Trolleybat vehicle" section) 30 + 31 +== Improvements == 32 + 33 +* checking the continuous charge current limit only if the "Use continuous charge current limit" flag is set in the "External equipment - Unibat vehicle - General parameters" section 34 +* Unibat: transition to charging mode according to the condition EESCD=7 35 + 36 +== Fixes == 37 + 38 +* resolving the problem of completing the initialization process before the power switch voltage stabilizes 39 +* Unibat: prevent the "Charge request" and "Discharge request" signals from being reset if the Unibat vehicle goes offline (the signals are controlled in the Unibat state machine) 40 + 41 += v3.7.1 = 42 + 43 +[[BMS_Main_3X_v3.7.1.bin>>FileManager.BMS_Main_3X_v3\.7\.1\.bin]] 44 + 45 +== Fixes == 46 + 47 +* Unibat: do not send the insulation error DTC if the IMD goes offline when the battery system is in the shutdown mode 48 + 6 6 = v3.7.0 = 7 7 8 8 [[BMS_Main_3X_v3.7.0.bin>>FileManager.BMS_Main_3X_v3\.7\.0\.bin]]