... ... @@ -3,45 +3,6 @@
3 3  BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
4 4  )))
5 5  
6 -= v3.7.0 =
7 -
8 -[[BMS_Main_3X_v3.7.0.bin>>FileManager.BMS_Main_3X_v3\.7\.0\.bin]]
9 -
10 -== Features ==
11 -
12 -* new profile section with global battery status, which includes total charge and energy counters, total operating time, contactor opening count, etc. (see the "Profile" tab in the Unified monitor)
13 -* new total charge counters (plus and minus)
14 -
15 -== Improvements ==
16 -
17 -* Unibat: new flag to set the custom value (=3) for the EESCD signal (see the "External equipment - Unibat vehicle - General parameters" section)
18 -* Unibat: new bit field to ignore internal errors that cause battery shutdown (see the "External equipment - Unibat vehicle - General parameters" section)
19 -* Unibat: sending a new packet containing the continuous charge current limit
20 -
21 -== Fixes ==
22 -
23 -* optimization of the logging process, minimizing the time to open the next log file if the current one is full
24 -* resolving the stability problem when the SD card is full
25 -* Unibat: prevent sending module online statuses if the power down condition is met
26 -* Unibat: small fixes
27 -
28 -= v3.6.2 =
29 -
30 -[[BMS_Main_3X_v3.6.2.bin>>FileManager.BMS_Main_3X_v3\.6\.2\.bin]]
31 -
32 -== Improvements ==
33 -
34 -* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V
35 -* Unibat: new flag that allows to hide the insulation testing status when repeating measurements (see the "External equipment - Unibat vehicle" section)
36 -* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all CAN3 (BMS) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address
37 -
38 -== Fixes ==
39 -
40 -* resolving the issue of false warnings indicating that the battery current exceeds the current limits (affects Unibat vehicle)
41 -* Unibat: changes that make it so that the output period is responsible for only 4 messages, not for all messages (see the "External equipment - Unibat vehicle" section)
42 -* Unibat: resolving the issue of TP messages not being sent if the transport is already transmitting something at the time of the request
43 -* corrections of typos in parameter descriptions
44 -
45 45  = v3.6.1 =
46 46  
47 47  [[BMS_Main_3X_v3.6.1.bin>>FileManager.BMS_Main_3X_v3\.6\.1\.bin]]