Changes for page BMS Main 3X
Last modified by Admin on 2025/10/27 11:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,63 +3,6 @@ 3 3 BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 -= v3.6.2 = 7 - 8 -[[BMS_Main_3X_v3.6.2.bin>>FileManager.BMS_Main_3X_v3\.6\.2\.bin]] 9 - 10 -== Improvements == 11 - 12 -* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V 13 -* Unibat: new flag that allows to hide the insulation testing status when repeating measurements (see the "External equipment - Unibat vehicle" section) 14 -* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all CAN3 (BMS) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address 15 - 16 -== Fixes == 17 - 18 -* resolving the issue of false warnings indicating that the battery current exceeds the current limits (affects Unibat vehicle) 19 -* Unibat: changes that make it so that the output period is responsible for only 4 messages, not for all messages (see the "External equipment - Unibat vehicle" section) 20 -* Unibat: resolving the issue of TP messages not being sent if the transport is already transmitting something at the time of the request 21 -* corrections of typos in parameter descriptions 22 - 23 -= v3.6.1 = 24 - 25 -[[BMS_Main_3X_v3.6.1.bin>>FileManager.BMS_Main_3X_v3\.6\.1\.bin]] 26 - 27 -== Improvements == 28 - 29 -* new parameters for switching to the sum of battery modules' currents if the current sensor error is detected or the sensor is saturated (see the "Inputs - Current sensor" section) 30 -* new flag allowing to swap CAN2 (int) and CAN3 (BMS) interfaces (see the "Connectivity" section under the service account) 31 - 32 -= v3.6.0 = 33 - 34 -[[BMS_Main_3X_v3.6.0.bin>>FileManager.BMS_Main_3X_v3\.6\.0\.bin]] 35 - 36 -== Features == 37 - 38 -* Unibat: refined algorithms and new parameters to meet requirements of version 8.5 of the logic (protocol v6.1) 39 - 40 -== Improvements == 41 - 42 -* new flag enabling fast current measurements (see the "Signals - Current sensor" section) 43 -* new parameters to ignore the specified errors when setting the critical error (see the "Protections - Critical error" section) 44 -* displaying HV calibration values for the service account (see the "Service - Calibration" section) 45 -* Unibat: structuring parameters into subgroups: "General parameters", "Battery parameters", "Diagnostic parameters", "Power limiting parameters", "Battery version" (see the "External equipment - Unibat vehicle" section) 46 - 47 -= v3.5.0 = 48 - 49 -[[BMS_Main_3X_v3.5.0.bin>>FileManager.BMS_Main_3X_v3\.5\.0\.bin]] 50 - 51 -== Features == 52 - 53 -* support for sending battery state and events via MQTT protocol via Wi-Fi or cellular network (see the "Service - MQTT" section) 54 - 55 -== Improvements == 56 - 57 -* support for secure (TLS) connections in BMS GSM v1 and v2 drivers 58 - 59 -== Fixes == 60 - 61 -* synchronization of the precharge procedure with the charge/discharge algorithms, so that precharge is stopped if charging and discharging are prohibited 62 - 63 63 = v3.4.0 = 64 64 65 65 [[BMS_Main_3X_v3.4.0.bin>>FileManager.BMS_Main_3X_v3\.4\.0\.bin]]