Changes for page BMS Main 3X

Last modified by Admin on 2025/10/27 11:43

From version 17.1
edited by Admin
on 2025/10/06 04:50
Change comment: There is no comment for this version
To version 11.1
edited by Admin
on 2025/04/14 10:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,96 +3,6 @@
3 3  BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
4 4  )))
5 5  
6 -= v3.6.1 =
7 -
8 -[[BMS_Main_3X_v3.6.1.bin>>FileManager.BMS_Main_3X_v3\.6\.1\.bin]]
9 -
10 -== Improvements ==
11 -
12 -* new parameters for switching to the sum of battery modules' currents if the current sensor error is detected or the sensor is saturated (see the "Inputs - Current sensor" section)
13 -* new flag allowing to swap CAN2 (int) and CAN3 (BMS) interfaces (see the "Connectivity" section under the service account)
14 -
15 -= v3.6.0 =
16 -
17 -[[BMS_Main_3X_v3.6.0.bin>>FileManager.BMS_Main_3X_v3\.6\.0\.bin]]
18 -
19 -== Features ==
20 -
21 -* Unibat: refined algorithms and new parameters to meet requirements of version 8.5 of the logic (protocol v6.1)
22 -
23 -== Improvements ==
24 -
25 -* new flag enabling fast current measurements (see the "Signals - Current sensor" section)
26 -* new parameters to ignore the specified errors when setting the critical error (see the "Protections - Critical error" section)
27 -* displaying HV calibration values for the service account (see the "Service - Calibration" section)
28 -* Unibat: structuring parameters into subgroups: "General parameters", "Battery parameters", "Diagnostic parameters", "Power limiting parameters", "Battery version" (see the "External equipment - Unibat vehicle" section)
29 -
30 -= v3.5.0 =
31 -
32 -[[BMS_Main_3X_v3.5.0.bin>>FileManager.BMS_Main_3X_v3\.5\.0\.bin]]
33 -
34 -== Features ==
35 -
36 -* support for sending battery state and events via MQTT protocol via Wi-Fi or cellular network (see the "Service - MQTT" section)
37 -
38 -== Improvements ==
39 -
40 -* support for secure (TLS) connections in BMS GSM v1 and v2 drivers
41 -
42 -== Fixes ==
43 -
44 -* synchronization of the precharge procedure with the charge/discharge algorithms, so that precharge is stopped if charging and discharging are prohibited
45 -
46 -= v3.4.0 =
47 -
48 -[[BMS_Main_3X_v3.4.0.bin>>FileManager.BMS_Main_3X_v3\.4\.0\.bin]]
49 -
50 -== Features ==
51 -
52 -* new protection checking that the voltage of joined battery modules is equal to the voltage before contactors (the "High voltage 1" value). If this is not the case, the error "Battery voltage mismatch" is generated (see the "Protections - Battery voltage" section)
53 -
54 -== Improvements ==
55 -
56 -* new CLI command "find-log" which finds a log file containing a specified timestamp
57 -* ability to acknowledge battery module errors via CLI (see the "Service - Errors journal" section) and Modbus protocol
58 -
59 -== Fixes ==
60 -
61 -* resolving the issue of rebooting the device if formatting the SD card is activated
62 -
63 -= v3.3.0 =
64 -
65 -[[BMS_Main_3X_v3.3.0.bin>>FileManager.BMS_Main_3X_v3\.3\.0\.bin]]
66 -
67 -== Features ==
68 -
69 -* ability to calibrate high voltage measuring means, available starting with the service account (see the "Service - Calibration" section)
70 -
71 -== Improvements ==
72 -
73 -* new type of temperature sensors: NTC 10k B25/50=3380K (see the "Signals - Temperature sensors" section)
74 -
75 -
76 -= v3.2.5 =
77 -
78 -[[BMS_Main_3X_v3.2.5.bin>>FileManager.BMS_Main_3X_v3\.2\.5\.bin]]
79 -
80 -== Improvements ==
81 -
82 -* dynamic calculation of data transfer schedule for optimal communication with a large number of battery modules
83 -* ability to complete device initialization after the set timeout has expired and the minimum number of modules has been detected (see the "Control - Initialization" section)
84 -* 30 second delay when remounting SD card after detecting mount error
85 -* saving the number of joined modules in log files
86 -* Unibat: new flag disabling insulation measurement
87 -* Unibat: calculation of the battery current depending on the connection variant of current sensors
88 -* Unibat: preventing HVILS changes if the battery is in power-down state
89 -
90 -== Fixes ==
91 -
92 -* resolving the problem of ignoring the parameter that selects the connection variant of current sensors
93 -* Unibat: corrections in message identifiers HVESSS1, HVESSD2, HVESSD3, HVESSD8, storing battery module data
94 -* Unibat: corrections in HVESSCFG message priority
95 -