Changes for page BMS Main 3X
Last modified by Admin on 2026/02/18 13:39
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +1,112 @@ 1 1 (% class="box infomessage" %) 2 2 ((( 3 -BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3. 5\. Firmware update.WebHome]].3 +BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v3.8.2 = 7 + 8 +[[BMS_Main_3X_v3.8.2.bin>>FileManager.BMS_Main_3X_v3\.8\.2\.bin]] 9 + 10 +== Improvements == 11 + 12 +* Unibat: preventing the reset of the HVBPITS and HVBPITR signals if the device shutdown was caused by the insulation fault 13 + 14 +== Fixes == 15 + 16 +* Unibat: charge current limit protection is disabled in charge mode only when the "Use continuous charge current limit" flag is set 17 +* Unibat: discharge current limit protection is enabled regardless of whether the battery is in discharge or charge mode 18 + 19 += v3.8.1 = 20 + 21 +[[BMS_Main_3X_v3.8.1.bin>>FileManager.BMS_Main_3X_v3\.8\.1\.bin]] 22 + 23 +== Improvements == 24 + 25 +* setting and clearing the "Voltage unbalance" errors without delays 26 +* new CAN bus speed is not applied until the device is rebooted 27 +* logging the following new parameters: "UnibatState", "UnibatOperationalModeState", "Keyrun", "ChargeOn" 28 +* Unibat: ability to shutdown the battery if its SOC is too low (see the "External equipment - Unibat vehicle - Diagnostic parameters" section) 29 +* Unibat: change the resolution of parameters CC and DC from 0.01 to 0.1 Ah/bit 30 +* Unibat: do not turn on the amber lamp if the actual battery SOC is equal to the configured maximum operational SOC 31 + 32 +== Fixes == 33 + 34 +* resolving the problem of completing the initialization process before the power switch voltage stabilizes 35 + 36 += v3.8.0 = 37 + 38 +[[BMS_Main_3X_v3.8.0.bin>>FileManager.BMS_Main_3X_v3\.8\.0\.bin]] 39 + 40 +== Features == 41 + 42 +* support for the Trolleybat vehicle (see the "External equipment - Trolleybat vehicle" section) 43 + 44 +== Improvements == 45 + 46 +* checking the continuous charge current limit only if the "Use continuous charge current limit" flag is set in the "External equipment - Unibat vehicle - General parameters" section 47 +* Unibat: transition to charging mode according to the condition EESCD=7 48 + 49 +== Fixes == 50 + 51 +* resolving the problem of completing the initialization process before the power switch voltage stabilizes 52 +* Unibat: prevent the "Charge request" and "Discharge request" signals from being reset if the Unibat vehicle goes offline (the signals are controlled in the Unibat state machine) 53 + 54 += v3.7.1 = 55 + 56 +[[BMS_Main_3X_v3.7.1.bin>>FileManager.BMS_Main_3X_v3\.7\.1\.bin]] 57 + 58 +== Fixes == 59 + 60 +* Unibat: do not send the insulation error DTC if the IMD goes offline when the battery system is in the shutdown mode 61 + 62 += v3.7.0 = 63 + 64 +[[BMS_Main_3X_v3.7.0.bin>>FileManager.BMS_Main_3X_v3\.7\.0\.bin]] 65 + 66 +== Features == 67 + 68 +* new profile section with global battery status, which includes total charge and energy counters, total operating time, contactor opening count, etc. (see the "Profile" tab in the Unified monitor) 69 +* new total charge counters (plus and minus) 70 + 71 +== Improvements == 72 + 73 +* Unibat: new flag to set the custom value (=3) for the EESCD signal (see the "External equipment - Unibat vehicle - General parameters" section) 74 +* Unibat: new bit field to ignore internal errors that cause battery shutdown (see the "External equipment - Unibat vehicle - General parameters" section) 75 +* Unibat: sending a new packet containing the continuous charge current limit 76 + 77 +== Fixes == 78 + 79 +* optimization of the logging process, minimizing the time to open the next log file if the current one is full 80 +* resolving the stability problem when the SD card is full 81 +* Unibat: prevent sending module online statuses if the power down condition is met 82 +* Unibat: small fixes 83 + 84 += v3.6.2 = 85 + 86 +[[BMS_Main_3X_v3.6.2.bin>>FileManager.BMS_Main_3X_v3\.6\.2\.bin]] 87 + 88 +== Improvements == 89 + 90 +* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V 91 +* Unibat: new flag that allows to hide the insulation testing status when repeating measurements (see the "External equipment - Unibat vehicle" section) 92 +* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all CAN3 (BMS) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address 93 + 94 +== Fixes == 95 + 96 +* resolving the issue of false warnings indicating that the battery current exceeds the current limits (affects Unibat vehicle) 97 +* Unibat: changes that make it so that the output period is responsible for only 4 messages, not for all messages (see the "External equipment - Unibat vehicle" section) 98 +* Unibat: resolving the issue of TP messages not being sent if the transport is already transmitting something at the time of the request 99 +* corrections of typos in parameter descriptions 100 + 101 += v3.6.1 = 102 + 103 +[[BMS_Main_3X_v3.6.1.bin>>FileManager.BMS_Main_3X_v3\.6\.1\.bin]] 104 + 105 +== Improvements == 106 + 107 +* new parameters for switching to the sum of battery modules' currents if the current sensor error is detected or the sensor is saturated (see the "Inputs - Current sensor" section) 108 +* new flag allowing to swap CAN2 (int) and CAN3 (BMS) interfaces (see the "Connectivity" section under the service account) 109 + 6 6 = v3.6.0 = 7 7 8 8 [[BMS_Main_3X_v3.6.0.bin>>FileManager.BMS_Main_3X_v3\.6\.0\.bin]]