Changes for page BMS Main 3X

Last modified by Admin on 2025/12/10 16:23

From version 16.1
edited by Admin
on 2025/10/03 09:01
Change comment: There is no comment for this version
To version 19.1
edited by Admin
on 2025/11/28 09:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,6 +3,54 @@
3 3  BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
4 4  )))
5 5  
6 += v3.7.0 =
7 +
8 +[[BMS_Main_3X_v3.7.0.bin>>FileManager.BMS_Main_3X_v3\.7\.0\.bin]]
9 +
10 +== Features ==
11 +
12 +* new profile section with global battery status, which includes total charge and energy counters, total operating time, contactor opening count, etc. (see the "Profile" tab in the Unified monitor)
13 +* new total charge counters (plus and minus)
14 +
15 +== Improvements ==
16 +
17 +* Unibat: new flag to set the custom value (=3) for the EESCD signal (see the "External equipment - Unibat vehicle - General parameters" section)
18 +* Unibat: new bit field to ignore internal errors that cause battery shutdown (see the "External equipment - Unibat vehicle - General parameters" section)
19 +* Unibat: sending a new packet containing the continuous charge current limit
20 +
21 +== Fixes ==
22 +
23 +* optimization of the logging process, minimizing the time to open the next log file if the current one is full
24 +* resolving the stability problem when the SD card is full
25 +* Unibat: prevent sending module online statuses if the power down condition is met
26 +* Unibat: small fixes
27 +
28 += v3.6.2 =
29 +
30 +[[BMS_Main_3X_v3.6.2.bin>>FileManager.BMS_Main_3X_v3\.6\.2\.bin]]
31 +
32 +== Improvements ==
33 +
34 +* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V
35 +* Unibat: new flag that allows to hide the insulation testing status when repeating measurements (see the "External equipment - Unibat vehicle" section)
36 +* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all CAN3 (BMS) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address
37 +
38 +== Fixes ==
39 +
40 +* resolving the issue of false warnings indicating that the battery current exceeds the current limits (affects Unibat vehicle)
41 +* Unibat: changes that make it so that the output period is responsible for only 4 messages, not for all messages (see the "External equipment - Unibat vehicle" section)
42 +* Unibat: resolving the issue of TP messages not being sent if the transport is already transmitting something at the time of the request
43 +* corrections of typos in parameter descriptions
44 +
45 += v3.6.1 =
46 +
47 +[[BMS_Main_3X_v3.6.1.bin>>FileManager.BMS_Main_3X_v3\.6\.1\.bin]]
48 +
49 +== Improvements ==
50 +
51 +* new parameters for switching to the sum of battery modules' currents if the current sensor error is detected or the sensor is saturated (see the "Inputs - Current sensor" section)
52 +* new flag allowing to swap CAN2 (int) and CAN3 (BMS) interfaces (see the "Connectivity" section under the service account)
53 +