Changes for page BMS Main 3X
                  Last modified by Admin on 2025/10/27 11:43
              
      Summary
- 
          Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
- 
      - Content
-   ... ... @@ -3,54 +3,6 @@ 3 3 BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 -= v3.6.0 = 7 - 8 -[[BMS_Main_3X_v3.6.0.bin>>FileManager.BMS_Main_3X_v3\.6\.0\.bin]] 9 - 10 -== Features == 11 - 12 -* Unibat: refined algorithms and new parameters to meet requirements of version 8.5 of the logic (protocol v6.1) 13 - 14 -== Improvements == 15 - 16 -* new flag enabling fast current measurements (see the "Signals - Current sensor" section) 17 -* new parameters to ignore the specified errors when setting the critical error (see the "Protections - Critical error" section) 18 -* displaying HV calibration values for the service account (see the "Service - Calibration" section) 19 -* Unibat: structuring parameters into subgroups: "General parameters", "Battery parameters", "Diagnostic parameters", "Power limiting parameters", "Battery version" (see the "External equipment - Unibat vehicle" section) 20 - 21 -= v3.5.0 = 22 - 23 -[[BMS_Main_3X_v3.5.0.bin>>FileManager.BMS_Main_3X_v3\.5\.0\.bin]] 24 - 25 -== Features == 26 - 27 -* support for sending battery state and events via MQTT protocol via Wi-Fi or cellular network (see the "Service - MQTT" section) 28 - 29 -== Improvements == 30 - 31 -* support for secure (TLS) connections in BMS GSM v1 and v2 drivers 32 - 33 -== Fixes == 34 - 35 -* synchronization of the precharge procedure with the charge/discharge algorithms, so that precharge is stopped if charging and discharging are prohibited 36 - 37 -= v3.4.0 = 38 - 39 -[[BMS_Main_3X_v3.4.0.bin>>FileManager.BMS_Main_3X_v3\.4\.0\.bin]] 40 - 41 -== Features == 42 - 43 -* new protection checking that the voltage of joined battery modules is equal to the voltage before contactors (the "High voltage 1" value). If this is not the case, the error "Battery voltage mismatch" is generated (see the "Protections - Battery voltage" section) 44 - 45 -== Improvements == 46 - 47 -* new CLI command "find-log" which finds a log file containing a specified timestamp 48 -* ability to acknowledge battery module errors via CLI (see the "Service - Errors journal" section) and Modbus protocol 49 - 50 -== Fixes == 51 - 52 -* resolving the issue of rebooting the device if formatting the SD card is activated 53 - 54 54 = v3.3.0 = 55 55 56 56 [[BMS_Main_3X_v3.3.0.bin>>FileManager.BMS_Main_3X_v3\.3\.0\.bin]] 
 
 
  