Changes for page BMS Main 3X
Last modified by Admin on 2026/01/20 11:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +1,113 @@ 1 1 (% class="box infomessage" %) 2 2 ((( 3 -BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3. 5\. Firmware update.WebHome]].3 +BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v3.8.0 = 7 + 8 +[[BMS_Main_3X_v3.8.0.bin>>FileManager.BMS_Main_3X_v3\.8\.0\.bin]] 9 + 10 +== Features == 11 + 12 +* support for the Trolleybat vehicle (see the "External equipment - Trolleybat vehicle" section) 13 + 14 +== Improvements == 15 + 16 +* checking the continuous charge current limit only if the "Use continuous charge current limit" flag is set in the "External equipment - Unibat vehicle - General parameters" section 17 +* Unibat: transition to charging mode according to the condition EESCD=7 18 + 19 +== Fixes == 20 + 21 +* resolving the problem of completing the initialization process before the power switch voltage stabilizes 22 +* Unibat: prevent the "Charge request" and "Discharge request" signals from being reset if the Unibat vehicle goes offline (the signals are controlled in the Unibat state machine) 23 + 24 += v3.7.1 = 25 + 26 +[[BMS_Main_3X_v3.7.1.bin>>FileManager.BMS_Main_3X_v3\.7\.1\.bin]] 27 + 28 +== Fixes == 29 + 30 +* Unibat: do not send the insulation error DTC if the IMD goes offline when the battery system is in the shutdown mode 31 + 32 += v3.7.0 = 33 + 34 +[[BMS_Main_3X_v3.7.0.bin>>FileManager.BMS_Main_3X_v3\.7\.0\.bin]] 35 + 36 +== Features == 37 + 38 +* new profile section with global battery status, which includes total charge and energy counters, total operating time, contactor opening count, etc. (see the "Profile" tab in the Unified monitor) 39 +* new total charge counters (plus and minus) 40 + 41 +== Improvements == 42 + 43 +* Unibat: new flag to set the custom value (=3) for the EESCD signal (see the "External equipment - Unibat vehicle - General parameters" section) 44 +* Unibat: new bit field to ignore internal errors that cause battery shutdown (see the "External equipment - Unibat vehicle - General parameters" section) 45 +* Unibat: sending a new packet containing the continuous charge current limit 46 + 47 +== Fixes == 48 + 49 +* optimization of the logging process, minimizing the time to open the next log file if the current one is full 50 +* resolving the stability problem when the SD card is full 51 +* Unibat: prevent sending module online statuses if the power down condition is met 52 +* Unibat: small fixes 53 + 54 += v3.6.2 = 55 + 56 +[[BMS_Main_3X_v3.6.2.bin>>FileManager.BMS_Main_3X_v3\.6\.2\.bin]] 57 + 58 +== Improvements == 59 + 60 +* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V 61 +* Unibat: new flag that allows to hide the insulation testing status when repeating measurements (see the "External equipment - Unibat vehicle" section) 62 +* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all CAN3 (BMS) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address 63 + 64 +== Fixes == 65 + 66 +* resolving the issue of false warnings indicating that the battery current exceeds the current limits (affects Unibat vehicle) 67 +* Unibat: changes that make it so that the output period is responsible for only 4 messages, not for all messages (see the "External equipment - Unibat vehicle" section) 68 +* Unibat: resolving the issue of TP messages not being sent if the transport is already transmitting something at the time of the request 69 +* corrections of typos in parameter descriptions 70 + 71 += v3.6.1 = 72 + 73 +[[BMS_Main_3X_v3.6.1.bin>>FileManager.BMS_Main_3X_v3\.6\.1\.bin]] 74 + 75 +== Improvements == 76 + 77 +* new parameters for switching to the sum of battery modules' currents if the current sensor error is detected or the sensor is saturated (see the "Inputs - Current sensor" section) 78 +* new flag allowing to swap CAN2 (int) and CAN3 (BMS) interfaces (see the "Connectivity" section under the service account) 79 + 80 += v3.6.0 = 81 + 82 +[[BMS_Main_3X_v3.6.0.bin>>FileManager.BMS_Main_3X_v3\.6\.0\.bin]] 83 + 84 +== Features == 85 + 86 +* Unibat: refined algorithms and new parameters to meet requirements of version 8.5 of the logic (protocol v6.1) 87 + 88 +== Improvements == 89 + 90 +* new flag enabling fast current measurements (see the "Signals - Current sensor" section) 91 +* new parameters to ignore the specified errors when setting the critical error (see the "Protections - Critical error" section) 92 +* displaying HV calibration values for the service account (see the "Service - Calibration" section) 93 +* Unibat: structuring parameters into subgroups: "General parameters", "Battery parameters", "Diagnostic parameters", "Power limiting parameters", "Battery version" (see the "External equipment - Unibat vehicle" section) 94 + 95 += v3.5.0 = 96 + 97 +[[BMS_Main_3X_v3.5.0.bin>>FileManager.BMS_Main_3X_v3\.5\.0\.bin]] 98 + 99 +== Features == 100 + 101 +* support for sending battery state and events via MQTT protocol via Wi-Fi or cellular network (see the "Service - MQTT" section) 102 + 103 +== Improvements == 104 + 105 +* support for secure (TLS) connections in BMS GSM v1 and v2 drivers 106 + 107 +== Fixes == 108 + 109 +* synchronization of the precharge procedure with the charge/discharge algorithms, so that precharge is stopped if charging and discharging are prohibited 110 + 6 6 = v3.4.0 = 7 7 8 8 [[BMS_Main_3X_v3.4.0.bin>>FileManager.BMS_Main_3X_v3\.4\.0\.bin]]