Changes for page BMS Main 3X
Last modified by Admin on 2025/12/10 16:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,6 +3,85 @@ 3 3 BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v3.7.0 = 7 + 8 +[[BMS_Main_3X_v3.7.0.bin>>FileManager.BMS_Main_3X_v3\.7\.0\.bin]] 9 + 10 +== Features == 11 + 12 +* new profile section with global battery status, which includes total charge and energy counters, total operating time, contactor opening count, etc. (see the "Profile" tab in the Unified monitor) 13 +* new total charge counters (plus and minus) 14 + 15 +== Improvements == 16 + 17 +* Unibat: new flag to set the custom value (=3) for the EESCD signal (see the "External equipment - Unibat vehicle - General parameters" section) 18 +* Unibat: new bit field to ignore internal errors that cause battery shutdown (see the "External equipment - Unibat vehicle - General parameters" section) 19 +* Unibat: sending a new packet containing the continuous charge current limit 20 + 21 +== Fixes == 22 + 23 +* optimization of the logging process, minimizing the time to open the next log file if the current one is full 24 +* resolving the stability problem when the SD card is full 25 +* Unibat: prevent sending module online statuses if the power down condition is met 26 +* Unibat: small fixes 27 + 28 += v3.6.2 = 29 + 30 +[[BMS_Main_3X_v3.6.2.bin>>FileManager.BMS_Main_3X_v3\.6\.2\.bin]] 31 + 32 +== Improvements == 33 + 34 +* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V 35 +* Unibat: new flag that allows to hide the insulation testing status when repeating measurements (see the "External equipment - Unibat vehicle" section) 36 +* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all CAN3 (BMS) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address 37 + 38 +== Fixes == 39 + 40 +* resolving the issue of false warnings indicating that the battery current exceeds the current limits (affects Unibat vehicle) 41 +* Unibat: changes that make it so that the output period is responsible for only 4 messages, not for all messages (see the "External equipment - Unibat vehicle" section) 42 +* Unibat: resolving the issue of TP messages not being sent if the transport is already transmitting something at the time of the request 43 +* corrections of typos in parameter descriptions 44 + 45 += v3.6.1 = 46 + 47 +[[BMS_Main_3X_v3.6.1.bin>>FileManager.BMS_Main_3X_v3\.6\.1\.bin]] 48 + 49 +== Improvements == 50 + 51 +* new parameters for switching to the sum of battery modules' currents if the current sensor error is detected or the sensor is saturated (see the "Inputs - Current sensor" section) 52 +* new flag allowing to swap CAN2 (int) and CAN3 (BMS) interfaces (see the "Connectivity" section under the service account) 53 + 54 += v3.6.0 = 55 + 56 +[[BMS_Main_3X_v3.6.0.bin>>FileManager.BMS_Main_3X_v3\.6\.0\.bin]] 57 + 58 +== Features == 59 + 60 +* Unibat: refined algorithms and new parameters to meet requirements of version 8.5 of the logic (protocol v6.1) 61 + 62 +== Improvements == 63 + 64 +* new flag enabling fast current measurements (see the "Signals - Current sensor" section) 65 +* new parameters to ignore the specified errors when setting the critical error (see the "Protections - Critical error" section) 66 +* displaying HV calibration values for the service account (see the "Service - Calibration" section) 67 +* Unibat: structuring parameters into subgroups: "General parameters", "Battery parameters", "Diagnostic parameters", "Power limiting parameters", "Battery version" (see the "External equipment - Unibat vehicle" section) 68 + 69 += v3.5.0 = 70 + 71 +[[BMS_Main_3X_v3.5.0.bin>>FileManager.BMS_Main_3X_v3\.5\.0\.bin]] 72 + 73 +== Features == 74 + 75 +* support for sending battery state and events via MQTT protocol via Wi-Fi or cellular network (see the "Service - MQTT" section) 76 + 77 +== Improvements == 78 + 79 +* support for secure (TLS) connections in BMS GSM v1 and v2 drivers 80 + 81 +== Fixes == 82 + 83 +* synchronization of the precharge procedure with the charge/discharge algorithms, so that precharge is stopped if charging and discharging are prohibited 84 + 6 6 = v3.4.0 = 7 7 8 8 [[BMS_Main_3X_v3.4.0.bin>>FileManager.BMS_Main_3X_v3\.4\.0\.bin]]