Changes for page BMS Main 3X

Last modified by Admin on 2025/09/03 10:30

From version 13.1
edited by Admin
on 2025/07/08 05:10
Change comment: There is no comment for this version
To version 14.1
edited by Admin
on 2025/07/17 12:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,6 +3,23 @@
3 3  BMS Main 3X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
4 4  )))
5 5  
6 += v3.4.0 =
7 +
8 +[[BMS_Main_3X_v3.4.0.bin>>FileManager.BMS_Main_3X_v3\.4\.0\.bin]]
9 +
10 +== Features ==
11 +
12 +* new protection checking that the voltage of joined battery modules is equal to the voltage before contactors (the "High voltage 1" value). If this is not the case, the error "Battery voltage mismatch" is generated (see the "Protections - Battery voltage" section)
13 +
14 +== Improvements ==
15 +
16 +* new CLI command "find-log" which finds a log file containing a specified timestamp
17 +* ability to acknowledge battery module errors via CLI (see the "Service - Errors journal" section) and Modbus protocol
18 +
19 +== Fixes ==
20 +
21 +* resolving the issue of rebooting the device if formatting the SD card is activated
22 +
6 6  = v3.3.0 =
7 7  
8 8  [[BMS_Main_3X_v3.3.0.bin>>FileManager.BMS_Main_3X_v3\.3\.0\.bin]]