Changes for page BMS Main 3X
Last modified by Admin on 2025/02/18 14:58
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Tags
-
... ... @@ -1,0 +1,1 @@ 1 +BMS Main 3X - Content
-
... ... @@ -1,7 +1,31 @@ 1 -= 3.1.1 = 1 +(% class="wikigeneratedid" %) 2 +BMS Main 3X firmware update procedure is described [[here>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%203/5.%20Firmware%20update/]]. 2 2 3 -... 4 +(% class="wikigeneratedid" %) 5 +v3.2.0 4 4 7 +(% class="wikigeneratedid" %) 8 +[[BMS_Main_3X_v3.2.0.bin>>FileManager.BMS_Main_3X_v3\.2\.0\.bin]] 9 + 10 +== Features == 11 + 12 +* new algorithm in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithm is preferred in the battery systems with one contactor 13 +* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 14 +* new Max-Min algorithm for calculating the final battery SOC in the "Control - Calculation" section 15 +* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 16 +* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 17 + 18 +== Improvements == 19 + 20 +* ability to finish device initialization even if the number of battery modules found is less than the number of modules enabled 21 +* ability to configure and monitor the device via the CAN1 (ext) bus 22 +* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 23 +* Unibat: support for functional description v3.5 (protocol v1.5) 24 + 25 += v3.1.1 = 26 + 27 +[[BMS_Main_3X_v3.1.1.bin>>FileManager.BMS_Main_3X_v3\.1\.1\.bin]] 28 + 5 5 == Fixes == 6 6 7 7 * resolving the problem of incorrect range of temperature parameter values (in the "Control - Coolant pump" section) ... ... @@ -9,11 +9,11 @@ 9 9 * resolving the problem of writing the device's working time to a non-volatile memory very often 10 10 * resolving the issue of preparing battery module states written to Modbus registers 11 11 12 -3.1.0 36 += v3.1.0 = 13 13 14 -... 38 +[[BMS_Main_3X_v3.1.0.bin>>FileManager.BMS_Main_3X_v3\.1\.0\.bin]] 15 15 16 -Features 40 +== Features == 17 17 18 18 * new parameter to set the minimum number of battery modules allowed to join (see the "Control - Charge" and "Control - Discharge" sections) 19 19 * ability to rejoin battery modules if their voltage is close to the battery voltage (see the "Control - Charge" and "Control - Discharge" sections) ... ... @@ -21,8 +21,12 @@ 21 21 * new internal signal "General error (modules)" which is the logical sum of the "General error" signals from the battery modules 22 22 * new assignments "Critical error" and "General error (modules)" for the discrete outputs and power switches (see the "Signals - Output discrete signals - Assignments" and "Signals - Power switches - Assignments" sections) 23 23 24 -Improvements 48 +== Improvements == 25 25 26 -- use the measured voltage before contactors as the battery voltage if the "Control - High voltage" function is enabled 27 -- Unibat: new flag to enable sending a control message to start/stop ventilation fans installed in the battery modules (see the "External equipment - Unibat vehicle" section) 28 -- rearrangements in the settings sections, which are made to simplify the setup process 50 +* use the measured voltage before contactors as the battery voltage if the "Control - High voltage" function is enabled 51 +* Unibat: new flag to enable sending a control message to start/stop ventilation fans installed in the battery modules (see the "External equipment - Unibat vehicle" section) 52 +* rearrangements in the settings sections, which are made to simplify the setup process 53 + 54 +== Fixes == 55 + 56 +* Unibat: minor changes in the communication protocol