Wiki source code of BMS Main 3

Last modified by Admin on 2025/02/18 14:57

Hide last authors
Admin 10.1 1 (% class="box infomessage" %)
2 (((
Admin 7.1 3 BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
Admin 10.1 4 )))
Admin 6.1 5
Admin 11.1 6 = v2.2.1 =
7
Admin 12.1 8 [[BMS_Main_3_v2.2.1.bin>>FileManager.BMS_Main_3_v2\.2\.1\.bin]]
Admin 11.1 9
10 == Improvements ==
11
12 * increasing the smoothness of changing the current limit values
13 * ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section)
14 * extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.)
15
16 == Fixes ==
17
18 * resolving the issue of working with the Fronius charger over the CAN1 interface
19 * small internal fixes
20
Admin 8.1 21 = v2.2.0 =
Admin 7.2 22
Admin 9.1 23 [[BMS_Main_3_v2.2.0.bin>>FileManager.BMS_Main_3_v2\.2\.0\.bin]]
24
Admin 8.1 25 == Features ==
Admin 7.2 26
27 * support for the HYG Global CAN protocol version 2 (June 13, 2024)
28 * calculation of regenerated energy
29 * calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section
30 * new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section
31 * new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section)
32 * new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section)
33 * new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section
34 * new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
35 * ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections)
36 * improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section)
37 * ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section)
38
39 == Improvements ==
40
41 * ability to configure and monitor the device via the CAN1 (ext) bus
42 * placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section
43
44 == Fixes ==
45
46 * using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
47
Admin 4.1 48 = v2.1.1 =
Admin 1.1 49
Admin 3.1 50 [[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]]
51
Admin 1.1 52 == Improvements ==
53
54 * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Control - Cell balancing" section)
55
56 == Fixes ==
57
58 * resolving the possible problem of saving device parameters
59 * resolving the problem of writing the device's working time to a non-volatile memory very often
60
Admin 4.1 61 = v2.1.0 =
Admin 2.1 62
Admin 3.1 63 [[BMS_Main_3_v2.1.0.bin>>FileManager.BMS_Main_3_v2\.1\.0\.bin]]
64
Admin 2.1 65 == Features ==
66
67 * new algorithms in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithms are preferred in the battery systems with one contactor.
68 * selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Charge/Discharge", "Control - Discharge (AUX)", "Control - Heater", "Control - Cooler", "Protections - General error", "Control - Charging status", "Control - Discharging status" sections)
69 * new "Current limit error" which is set if the battery current exceeds the charging or discharging current limits (see the "Protections - Charge current limit" and "Protections - Discharge current limit" sections)
70 * new parameter to select the method of calculating the battery voltage: sum the cell voltages or use the measured voltage before contactors (see the "Control - Common settings" section)
71 * clearing the Discharging (AUX) signal if the cell voltage is too low (see the "Control - Discharge (AUX)" section)
72 * new assignment "Close External 1" for the discrete inputs (see the "Signals - Input discrete signals - Assignments" section)
73 * new assignment "External 1" for the discrete outputs and power switches (see the "Signals - Output discrete signals - Assignments" and "Signals - Power switches - Assignments" sections). The "External 1" output is directly controlled by the "Close External 1" command.
74