Wiki source code of BMS Main 3
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | (% class="wikigeneratedid" %) | ||
2 | BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. | ||
3 | |||
4 | = v2.1.1 = | ||
5 | |||
6 | [[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]] | ||
7 | |||
8 | == Improvements == | ||
9 | |||
10 | * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Control - Cell balancing" section) | ||
11 | |||
12 | == Fixes == | ||
13 | |||
14 | * resolving the possible problem of saving device parameters | ||
15 | * resolving the problem of writing the device's working time to a non-volatile memory very often | ||
16 | |||
17 | = v2.1.0 = | ||
18 | |||
19 | [[BMS_Main_3_v2.1.0.bin>>FileManager.BMS_Main_3_v2\.1\.0\.bin]] | ||
20 | |||
21 | == Features == | ||
22 | |||
23 | * new algorithms in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithms are preferred in the battery systems with one contactor. | ||
24 | * selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Charge/Discharge", "Control - Discharge (AUX)", "Control - Heater", "Control - Cooler", "Protections - General error", "Control - Charging status", "Control - Discharging status" sections) | ||
25 | * new "Current limit error" which is set if the battery current exceeds the charging or discharging current limits (see the "Protections - Charge current limit" and "Protections - Discharge current limit" sections) | ||
26 | * new parameter to select the method of calculating the battery voltage: sum the cell voltages or use the measured voltage before contactors (see the "Control - Common settings" section) | ||
27 | * clearing the Discharging (AUX) signal if the cell voltage is too low (see the "Control - Discharge (AUX)" section) | ||
28 | * new assignment "Close External 1" for the discrete inputs (see the "Signals - Input discrete signals - Assignments" section) | ||
29 | * new assignment "External 1" for the discrete outputs and power switches (see the "Signals - Output discrete signals - Assignments" and "Signals - Power switches - Assignments" sections). The "External 1" output is directly controlled by the "Close External 1" command. | ||
30 | |||
31 | == Improvements == | ||
32 | |||
33 | * rearrangements in the settings sections, which are made to simplify the setup process |