Wiki source code of BMS Main 3
Hide last authors
| author | version | line-number | content |
|---|---|---|---|
| |
1.1 | 1 | = 2.1.1 = |
| 2 | |||
| 3 | == Improvements == | ||
| 4 | |||
| 5 | * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Control - Cell balancing" section) | ||
| 6 | |||
| 7 | == Fixes == | ||
| 8 | |||
| 9 | * resolving the possible problem of saving device parameters | ||
| 10 | * resolving the problem of writing the device's working time to a non-volatile memory very often | ||
| 11 | |||
| |
2.1 | 12 | = 2.1.0 = |
| 13 | |||
| 14 | == Features == | ||
| 15 | |||
| 16 | * new algorithms in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithms are preferred in the battery systems with one contactor. | ||
| 17 | * selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Charge/Discharge", "Control - Discharge (AUX)", "Control - Heater", "Control - Cooler", "Protections - General error", "Control - Charging status", "Control - Discharging status" sections) | ||
| 18 | * new "Current limit error" which is set if the battery current exceeds the charging or discharging current limits (see the "Protections - Charge current limit" and "Protections - Discharge current limit" sections) | ||
| 19 | * new parameter to select the method of calculating the battery voltage: sum the cell voltages or use the measured voltage before contactors (see the "Control - Common settings" section) | ||
| 20 | * clearing the Discharging (AUX) signal if the cell voltage is too low (see the "Control - Discharge (AUX)" section) | ||
| 21 | * new assignment "Close External 1" for the discrete inputs (see the "Signals - Input discrete signals - Assignments" section) | ||
| 22 | * new assignment "External 1" for the discrete outputs and power switches (see the "Signals - Output discrete signals - Assignments" and "Signals - Power switches - Assignments" sections). The "External 1" output is directly controlled by the "Close External 1" command. | ||
| 23 | |||