Wiki source code of BMS Main 3
Hide last authors
| author | version | line-number | content |
|---|---|---|---|
| |
10.1 | 1 | (% class="box infomessage" %) |
| 2 | ((( | ||
| |
7.1 | 3 | BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. |
| |
10.1 | 4 | ))) |
| |
6.1 | 5 | |
| |
14.1 | 6 | = v2.2.3 = |
| 7 | |||
| 8 | [[BMS_Main_3_v2.2.3.bin>>FileManager.BMS_Main_3_v2\.2\.3\.bin]] | ||
| 9 | |||
| 10 | == Improvements == | ||
| 11 | |||
| 12 | * new parameter for setting the type of network to which the BMS GSM communication module connects (see the "Connectivity - Cellular" section) | ||
| 13 | |||
| 14 | == Fixes == | ||
| 15 | |||
| 16 | * resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells) | ||
| 17 | |||
| |
13.1 | 18 | = v2.2.2 = |
| 19 | |||
| 20 | [[BMS_Main_3_v2.2.2.bin>>FileManager.BMS_Main_3_v2\.2\.2\.bin]] | ||
| 21 | |||
| 22 | == Improvements == | ||
| 23 | |||
| 24 | * increasing the accuracy of resistance calculations | ||
| 25 | * new parameters for battery manufacturers: manufacturer name, hardware ID, software ID, configuration description, production date (see the "Service - User settings" section) | ||
| 26 | |||
| |
11.1 | 27 | = v2.2.1 = |
| 28 | |||
| |
12.1 | 29 | [[BMS_Main_3_v2.2.1.bin>>FileManager.BMS_Main_3_v2\.2\.1\.bin]] |
| |
11.1 | 30 | |
| 31 | == Improvements == | ||
| 32 | |||
| 33 | * increasing the smoothness of changing the current limit values | ||
| 34 | * ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) | ||
| 35 | * extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.) | ||
| 36 | |||
| 37 | == Fixes == | ||
| 38 | |||
| 39 | * resolving the issue of working with the Fronius charger over the CAN1 interface | ||
| 40 | * small internal fixes | ||
| 41 | |||
| |
8.1 | 42 | = v2.2.0 = |
| |
7.2 | 43 | |
| |
9.1 | 44 | [[BMS_Main_3_v2.2.0.bin>>FileManager.BMS_Main_3_v2\.2\.0\.bin]] |
| 45 | |||
| |
8.1 | 46 | == Features == |
| |
7.2 | 47 | |
| 48 | * support for the HYG Global CAN protocol version 2 (June 13, 2024) | ||
| 49 | * calculation of regenerated energy | ||
| 50 | * calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section | ||
| 51 | * new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section | ||
| 52 | * new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section) | ||
| 53 | * new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section) | ||
| 54 | * new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section | ||
| 55 | * new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively | ||
| 56 | * ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections) | ||
| 57 | * improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) | ||
| 58 | * ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) | ||
| 59 | |||
| 60 | == Improvements == | ||
| 61 | |||
| 62 | * ability to configure and monitor the device via the CAN1 (ext) bus | ||
| 63 | * placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section | ||
| 64 | |||
| 65 | == Fixes == | ||
| 66 | |||
| 67 | * using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals | ||
| 68 | |||
| |
4.1 | 69 | = v2.1.1 = |
| |
1.1 | 70 | |
| |
3.1 | 71 | [[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]] |
| 72 | |||
| |
1.1 | 73 | == Improvements == |
| 74 | |||
| 75 | * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Control - Cell balancing" section) | ||
| 76 | |||
| 77 | == Fixes == | ||
| 78 | |||
| 79 | * resolving the possible problem of saving device parameters | ||
| 80 | * resolving the problem of writing the device's working time to a non-volatile memory very often | ||
| 81 | |||
| |
4.1 | 82 | = v2.1.0 = |
| |
2.1 | 83 | |
| |
3.1 | 84 | [[BMS_Main_3_v2.1.0.bin>>FileManager.BMS_Main_3_v2\.1\.0\.bin]] |
| 85 | |||
| |
2.1 | 86 | == Features == |
| 87 | |||
| 88 | * new algorithms in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithms are preferred in the battery systems with one contactor. | ||
| 89 | * selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Charge/Discharge", "Control - Discharge (AUX)", "Control - Heater", "Control - Cooler", "Protections - General error", "Control - Charging status", "Control - Discharging status" sections) | ||
| 90 | * new "Current limit error" which is set if the battery current exceeds the charging or discharging current limits (see the "Protections - Charge current limit" and "Protections - Discharge current limit" sections) | ||
| 91 | * new parameter to select the method of calculating the battery voltage: sum the cell voltages or use the measured voltage before contactors (see the "Control - Common settings" section) | ||
| 92 | * clearing the Discharging (AUX) signal if the cell voltage is too low (see the "Control - Discharge (AUX)" section) | ||
| 93 | * new assignment "Close External 1" for the discrete inputs (see the "Signals - Input discrete signals - Assignments" section) | ||
| 94 | * new assignment "External 1" for the discrete outputs and power switches (see the "Signals - Output discrete signals - Assignments" and "Signals - Power switches - Assignments" sections). The "External 1" output is directly controlled by the "Close External 1" command. | ||
| 95 | |||
| 96 | == Improvements == | ||
| 97 | |||
| 98 | * rearrangements in the settings sections, which are made to simplify the setup process |