Changes for page BMS Main 3
Last modified by Admin on 2025/02/18 14:57
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Tags
-
... ... @@ -1,1 +1,0 @@ 1 -BMS Main 3 - Content
-
... ... @@ -1,37 +1,7 @@ 1 -(% class="wikigeneratedid" %) 2 -BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 1 += 2.1.1 = 3 3 4 -= v2.2.0 = 5 - 6 -== Features == 7 - 8 -* support for the HYG Global CAN protocol version 2 (June 13, 2024) 9 -* calculation of regenerated energy 10 -* calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section 11 -* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 12 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section) 13 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section) 14 -* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section 15 -* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively 16 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections) 17 -* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 18 -* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 19 - 20 20 == Improvements == 21 21 22 -* ability to configure and monitor the device via the CAN1 (ext) bus 23 -* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 24 - 25 -== Fixes == 26 - 27 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 28 - 29 -= v2.1.1 = 30 - 31 -[[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]] 32 - 33 -== Improvements == 34 - 35 35 * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Control - Cell balancing" section) 36 36 37 37 == Fixes == ... ... @@ -39,10 +39,8 @@ 39 39 * resolving the possible problem of saving device parameters 40 40 * resolving the problem of writing the device's working time to a non-volatile memory very often 41 41 42 -= v2.1.0 =12 += 2.1.0 = 43 43 44 -[[BMS_Main_3_v2.1.0.bin>>FileManager.BMS_Main_3_v2\.1\.0\.bin]] 45 - 46 46 == Features == 47 47 48 48 * new algorithms in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithms are preferred in the battery systems with one contactor.