... ... @@ -1,1 +1,0 @@
1 -BMS Main 3
Content
... ... @@ -1,37 +1,7 @@
1 -(% class="wikigeneratedid" %)
2 -BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
1 += 2.1.1 =
3 3  
4 -= v2.2.0 =
5 -
6 -== Features ==
7 -
8 -* support for the HYG Global CAN protocol version 2 (June 13, 2024)
9 -* calculation of regenerated energy
10 -* calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section
11 -* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section
12 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section)
13 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section)
14 -* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section
15 -* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
16 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections)
17 -* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section)
18 -* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section)
19 -
20 20  == Improvements ==
21 21  
22 -* ability to configure and monitor the device via the CAN1 (ext) bus
23 -* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section
24 -
25 -== Fixes ==
26 -
27 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
28 -
29 -= v2.1.1 =
30 -
31 -[[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]]
32 -
33 -== Improvements ==
34 -
35 35  * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Control - Cell balancing" section)
36 36  
37 37  == Fixes ==
... ... @@ -39,10 +39,8 @@
39 39  * resolving the possible problem of saving device parameters
40 40  * resolving the problem of writing the device's working time to a non-volatile memory very often
41 41  
42 -= v2.1.0 =
12 += 2.1.0 =
43 43  
44 -[[BMS_Main_3_v2.1.0.bin>>FileManager.BMS_Main_3_v2\.1\.0\.bin]]
45 -
46 46  == Features ==
47 47  
48 48  * new algorithms in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithms are preferred in the battery systems with one contactor.