... ... @@ -1,33 +1,6 @@
1 1  (% class="wikigeneratedid" %)
2 -BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
2 +BMS Main 3 firmware upgrade procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
3 3  
4 -(% class="wikigeneratedid" %)
5 -v2.2.0
6 -
7 -(% class="wikigeneratedid" %)
8 -Features
9 -
10 -* support for the HYG Global CAN protocol version 2 (June 13, 2024)
11 -* calculation of regenerated energy
12 -* calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section
13 -* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section
14 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section)
15 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section)
16 -* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section
17 -* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
18 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections)
19 -* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section)
20 -* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section)
21 -
22 -== Improvements ==
23 -
24 -* ability to configure and monitor the device via the CAN1 (ext) bus
25 -* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section
26 -
27 -== Fixes ==
28 -
29 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
30 -
31 31  = v2.1.1 =
32 32  
33 33  [[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]]