Changes for page BMS Main 3
Last modified by Admin on 2025/02/18 14:57
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Tags
-
... ... @@ -1,1 +1,0 @@ 1 -BMS Main 3 - Content
-
... ... @@ -1,39 +1,7 @@ 1 -(% class="wikigeneratedid" %) 2 -BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 1 += 2.1.1 = 3 3 4 -(% class="wikigeneratedid" %) 5 -v2.2.0 6 - 7 -(% class="wikigeneratedid" %) 8 -Features 9 - 10 -* support for the HYG Global CAN protocol version 2 (June 13, 2024) 11 -* calculation of regenerated energy 12 -* calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section 13 -* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 14 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section) 15 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section) 16 -* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section 17 -* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively 18 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections) 19 -* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 20 -* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 21 - 22 22 == Improvements == 23 23 24 -* ability to configure and monitor the device via the CAN1 (ext) bus 25 -* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 26 - 27 -== Fixes == 28 - 29 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 30 - 31 -= v2.1.1 = 32 - 33 -[[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]] 34 - 35 -== Improvements == 36 - 37 37 * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Control - Cell balancing" section) 38 38 39 39 == Fixes == ... ... @@ -41,20 +41,4 @@ 41 41 * resolving the possible problem of saving device parameters 42 42 * resolving the problem of writing the device's working time to a non-volatile memory very often 43 43 44 -= v2.1.0 = 45 - 46 -[[BMS_Main_3_v2.1.0.bin>>FileManager.BMS_Main_3_v2\.1\.0\.bin]] 47 - 48 -== Features == 49 - 50 -* new algorithms in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithms are preferred in the battery systems with one contactor. 51 -* selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Charge/Discharge", "Control - Discharge (AUX)", "Control - Heater", "Control - Cooler", "Protections - General error", "Control - Charging status", "Control - Discharging status" sections) 52 -* new "Current limit error" which is set if the battery current exceeds the charging or discharging current limits (see the "Protections - Charge current limit" and "Protections - Discharge current limit" sections) 53 -* new parameter to select the method of calculating the battery voltage: sum the cell voltages or use the measured voltage before contactors (see the "Control - Common settings" section) 54 -* clearing the Discharging (AUX) signal if the cell voltage is too low (see the "Control - Discharge (AUX)" section) 55 -* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input discrete signals - Assignments" section) 56 -* new assignment "External 1" for the discrete outputs and power switches (see the "Signals - Output discrete signals - Assignments" and "Signals - Power switches - Assignments" sections). The "External 1" output is directly controlled by the "Close External 1" command. 57 - 58 -== Improvements == 59 - 60 -* rearrangements in the settings sections, which are made to simplify the setup process 12 +2