Changes for page BMS Main 3
Last modified by Admin on 2025/02/18 14:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,33 @@ 1 1 (% class="wikigeneratedid" %) 2 2 BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 3 3 4 +(% class="wikigeneratedid" %) 5 +v2.2.0 6 + 7 +(% class="wikigeneratedid" %) 8 +Features 9 + 10 +* support for the HYG Global CAN protocol version 2 (June 13, 2024) 11 +* calculation of regenerated energy 12 +* calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section 13 +* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 14 +* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section) 15 +* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section) 16 +* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section 17 +* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively 18 +* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections) 19 +* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 20 +* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 21 + 22 +== Improvements == 23 + 24 +* ability to configure and monitor the device via the CAN1 (ext) bus 25 +* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 26 + 27 +== Fixes == 28 + 29 +* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 30 + 4 4 = v2.1.1 = 5 5 6 6 [[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]]