Changes for page BMS Main 3
Last modified by Admin on 2025/04/15 09:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,71 @@ 1 -(% class="wikigeneratedid" %) 1 +(% class="box infomessage" %) 2 +((( 2 2 BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 +))) 3 3 6 += v2.2.3 = 7 + 8 +[[BMS_Main_3_v2.2.3.bin>>FileManager.BMS_Main_3_v2\.2\.3\.bin]] 9 + 10 +== Improvements == 11 + 12 +* new parameter for setting the type of network to which the BMS GSM communication module connects (see the "Connectivity - Cellular" section) 13 + 14 +== Fixes == 15 + 16 +* resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells) 17 + 18 += v2.2.2 = 19 + 20 +[[BMS_Main_3_v2.2.2.bin>>FileManager.BMS_Main_3_v2\.2\.2\.bin]] 21 + 22 +== Improvements == 23 + 24 +* increasing the accuracy of resistance calculations 25 +* new parameters for battery manufacturers: manufacturer name, hardware ID, software ID, configuration description, production date (see the "Service - User settings" section) 26 + 27 += v2.2.1 = 28 + 29 +[[BMS_Main_3_v2.2.1.bin>>FileManager.BMS_Main_3_v2\.2\.1\.bin]] 30 + 31 +== Improvements == 32 + 33 +* increasing the smoothness of changing the current limit values 34 +* ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) 35 +* extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.) 36 + 37 +== Fixes == 38 + 39 +* resolving the issue of working with the Fronius charger over the CAN1 interface 40 +* small internal fixes 41 + 42 += v2.2.0 = 43 + 44 +[[BMS_Main_3_v2.2.0.bin>>FileManager.BMS_Main_3_v2\.2\.0\.bin]] 45 + 46 +== Features == 47 + 48 +* support for the HYG Global CAN protocol version 2 (June 13, 2024) 49 +* calculation of regenerated energy 50 +* calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section 51 +* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 52 +* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section) 53 +* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section) 54 +* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section 55 +* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively 56 +* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections) 57 +* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 58 +* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 59 + 60 +== Improvements == 61 + 62 +* ability to configure and monitor the device via the CAN1 (ext) bus 63 +* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 64 + 65 +== Fixes == 66 + 67 +* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 68 + 4 4 = v2.1.1 = 5 5 6 6 [[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]]