Changes for page BMS Main 3
Last modified by Admin on 2025/02/18 14:57
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Tags
-
... ... @@ -1,1 +1,0 @@ 1 -BMS Main 3 - Content
-
... ... @@ -1,10 +1,5 @@ 1 -(% class="wikigeneratedid" %) 2 -BMS Main 3 firmware upgrade procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 1 += 2.1.1 = 3 3 4 -= v2.1.1 = 5 - 6 -[[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]] 7 - 8 8 == Improvements == 9 9 10 10 * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Control - Cell balancing" section) ... ... @@ -14,10 +14,8 @@ 14 14 * resolving the possible problem of saving device parameters 15 15 * resolving the problem of writing the device's working time to a non-volatile memory very often 16 16 17 -= v2.1.0 =12 += 2.1.0 = 18 18 19 -[[BMS_Main_3_v2.1.0.bin>>FileManager.BMS_Main_3_v2\.1\.0\.bin]] 20 - 21 21 == Features == 22 22 23 23 * new algorithms in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithms are preferred in the battery systems with one contactor.