Changes for page BMS Main 3

Last modified by Admin on 2025/02/18 14:57

From version 6.1
edited by Admin
on 2024/12/11 12:48
Change comment: There is no comment for this version
To version 11.1
edited by Admin
on 2025/02/18 14:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,50 @@
1 -(% class="wikigeneratedid" %)
2 -BMS Main 3 firmware upgrade procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
1 +(% class="box infomessage" %)
2 +(((
3 +BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
4 +)))
3 3  
6 += v2.2.1 =
7 +
8 +...
9 +
10 +== Improvements ==
11 +
12 +* increasing the smoothness of changing the current limit values
13 +* ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section)
14 +* extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.)
15 +
16 +== Fixes ==
17 +
18 +* resolving the issue of working with the Fronius charger over the CAN1 interface
19 +* small internal fixes
20 +
21 += v2.2.0 =
22 +
23 +[[BMS_Main_3_v2.2.0.bin>>FileManager.BMS_Main_3_v2\.2\.0\.bin]]
24 +
25 +== Features ==
26 +
27 +* support for the HYG Global CAN protocol version 2 (June 13, 2024)
28 +* calculation of regenerated energy
29 +* calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section
30 +* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section
31 +* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section)
32 +* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section)
33 +* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section
34 +* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
35 +* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections)
36 +* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section)
37 +* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section)
38 +
39 +== Improvements ==
40 +
41 +* ability to configure and monitor the device via the CAN1 (ext) bus
42 +* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section
43 +
44 +== Fixes ==
45 +
46 +* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
47 +
4 4  = v2.1.1 =
5 5  
6 6  [[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]]