Changes for page BMS Main 3
Last modified by Admin on 2025/02/18 14:57
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Tags
-
... ... @@ -1,1 +1,0 @@ 1 -BMS Main 3 - Content
-
... ... @@ -1,10 +1,5 @@ 1 -(% class="wikigeneratedid" %) 2 -BMS Main 3 firmware upgrade procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 1 += 2.1.1 = 3 3 4 -= v2.1.1 = 5 - 6 -[[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]] 7 - 8 8 == Improvements == 9 9 10 10 * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Control - Cell balancing" section) ... ... @@ -14,20 +14,4 @@ 14 14 * resolving the possible problem of saving device parameters 15 15 * resolving the problem of writing the device's working time to a non-volatile memory very often 16 16 17 -= v2.1.0 = 18 - 19 -[[BMS_Main_3_v2.1.0.bin>>FileManager.BMS_Main_3_v2\.1\.0\.bin]] 20 - 21 -== Features == 22 - 23 -* new algorithms in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithms are preferred in the battery systems with one contactor. 24 -* selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Charge/Discharge", "Control - Discharge (AUX)", "Control - Heater", "Control - Cooler", "Protections - General error", "Control - Charging status", "Control - Discharging status" sections) 25 -* new "Current limit error" which is set if the battery current exceeds the charging or discharging current limits (see the "Protections - Charge current limit" and "Protections - Discharge current limit" sections) 26 -* new parameter to select the method of calculating the battery voltage: sum the cell voltages or use the measured voltage before contactors (see the "Control - Common settings" section) 27 -* clearing the Discharging (AUX) signal if the cell voltage is too low (see the "Control - Discharge (AUX)" section) 28 -* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input discrete signals - Assignments" section) 29 -* new assignment "External 1" for the discrete outputs and power switches (see the "Signals - Output discrete signals - Assignments" and "Signals - Power switches - Assignments" sections). The "External 1" output is directly controlled by the "Close External 1" command. 30 - 31 -== Improvements == 32 - 33 -* rearrangements in the settings sections, which are made to simplify the setup process 12 +2.1.1