Changes for page BMS Main 3
Last modified by Admin on 2025/02/18 14:57
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Tags
-
... ... @@ -1,0 +1,1 @@ 1 +BMS Main 3 - Content
-
... ... @@ -1,3 +1,35 @@ 1 +(% class="box infomessage" %) 2 +((( 3 +BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 +))) 5 + 6 += v2.2.0 = 7 + 8 +[[BMS_Main_3_v2.2.0.bin>>FileManager.BMS_Main_3_v2\.2\.0\.bin]] 9 + 10 +== Features == 11 + 12 +* support for the HYG Global CAN protocol version 2 (June 13, 2024) 13 +* calculation of regenerated energy 14 +* calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section 15 +* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 16 +* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section) 17 +* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section) 18 +* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section 19 +* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively 20 +* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections) 21 +* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 22 +* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 23 + 24 +== Improvements == 25 + 26 +* ability to configure and monitor the device via the CAN1 (ext) bus 27 +* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 28 + 29 +== Fixes == 30 + 31 +* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 32 + 1 1 = v2.1.1 = 2 2 3 3 [[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]]