Changes for page BMS Main 3

Last modified by Admin on 2026/02/28 03:27

From version 19.1
edited by Admin
on 2025/10/03 09:00
Change comment: There is no comment for this version
To version 22.3
edited by Admin
on 2026/02/05 03:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,8 +1,71 @@
1 1  (% class="box infomessage" %)
2 2  (((
3 -BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
3 +BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]].
4 4  )))
5 5  
6 += v2.9.0 =
7 +
8 +Features
9 +
10 +new flag that forces the "Ready to discharge" signal to clear when the "Low SOC" signal is generated (see the "Control - Discharging status" section)
11 +new input signal "Close External 2" which generates the new internal signal "External 2" which can be assigned to a discrete output or a power switch (see the "Signals - Input discrete signals - Assignments", "Signals - Output discrete signals - Assignments", and "Signals - Power switches - Assignments" sections)
12 +ability to configure the generation of "External 1" and "External 2" signals based on other internal signals as an alternative to the "Close External 1" and "Close External 2" commands (see the "Signals - External 1-2 signals" section)
13 +
14 +Improvements
15 +
16 +new flags for generating the "Ready to charge" and "Ready to discharge" signals using the actual cell voltage instead of the calculated open circuit voltage (see the "Control - Charging status" and "Control - Discharging status" sections)
17 +new flag the forces the device to wait for the "Charge request" and "Discharge request" signals to clear before reconnecting power contactors if the connection to the BMS Main X device is temporarily lost (see the "External equipment - BMS - Main X" section)
18 +new CAN bus speed is not applied until the device is rebooted
19 +logging the following new parameters: "Keyrun", "ChargeOn"
20 +
21 +Fixes
22 +
23 +resolving the problem of charge, discharge, and charge/discharge contactors closing when the "Precharge request" signal is set
24 +esolving the problem of completing the initialization process before the power switch voltage stabilizes
25 +- resolving the problem of resetting the SOC of some cells to zero when starting the device
26 +
27 += v2.8.1 =
28 +
29 +[[BMS_Main_3_v2.8.1.bin>>FileManager.BMS_Main_3_v2\.8\.1\.bin]]
30 +
31 +== Fixes ==
32 +
33 +* resolving the problem of incorrectly saving battery cell data
34 +* resolving the problem where the "HYG offline" error does not occur if the global HYG class is selected in the device settings
35 +
36 += v2.8.0 =
37 +
38 +[[BMS_Main_3_v2.8.0.bin>>FileManager.BMS_Main_3_v2\.8\.0\.bin]]
39 +
40 +== Features ==
41 +
42 +* new profile section with global battery status, which includes total charge and energy counters, total operating time, contactor switching count, etc. (see the "Profile" tab in the Unified monitor)
43 +* new total charge counters (plus and minus)
44 +* new SOH estimation algorithm that calculates SOH as a linear function of the total charge (minus) (see the "Control - SOH estimation" section)
45 +
46 +== Improvements ==
47 +
48 +* support for 32-bit BMS Logic serial numbers
49 +
50 +== Fixes ==
51 +
52 +* optimization of the logging process, minimizing the time to open the next log file if the current one is full
53 +* resolving the stability problem when the SD card is full
54 +
55 += v2.7.1 =
56 +
57 +[[BMS_Main_3_v2.7.1.bin>>FileManager.BMS_Main_3_v2\.7\.1\.bin]]
58 +
59 +== Improvements ==
60 +
61 +* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V
62 +* ability to generate the "Logic count error" also during BMS initialization (scanning of BMS Logic devices); new parameters for setting delays before/after generating/clearing the error (see the "Protections - Logic count" section)
63 +* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address
64 +
65 +== Fixes ==
66 +
67 +* small fixes in dynamic current maps
68 +
6 6  = v2.7.0 =
7 7  
8 8  [[BMS_Main_3_v2.7.0.bin>>FileManager.BMS_Main_3_v2\.7\.0\.bin]]