Changes for page BMS Main 3
Last modified by Admin on 2025/12/10 16:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +1,50 @@ 1 1 (% class="box infomessage" %) 2 2 ((( 3 -BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3. 5\. Firmware update.WebHome]].3 +BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v2.8.1 = 7 + 8 +[[BMS_Main_3_v2.8.1.bin>>FileManager.BMS_Main_3_v2\.8\.1\.bin]] 9 + 10 +== Fixes == 11 + 12 +* resolving the problem of incorrectly saving battery cell data 13 +* resolving the problem where the "HYG offline" error does not occur if the global HYG class is selected in the device settings 14 + 15 += v2.8.0 = 16 + 17 +[[BMS_Main_3_v2.8.0.bin>>FileManager.BMS_Main_3_v2\.8\.0\.bin]] 18 + 19 +== Features == 20 + 21 +* new profile section with global battery status, which includes total charge and energy counters, total operating time, contactor switching count, etc. (see the "Profile" tab in the Unified monitor) 22 +* new total charge counters (plus and minus) 23 +* new SOH estimation algorithm that calculates SOH as a linear function of the total charge (minus) (see the "Control - SOH estimation" section) 24 + 25 +== Improvements == 26 + 27 +* support for 32-bit BMS Logic serial numbers 28 + 29 +== Fixes == 30 + 31 +* optimization of the logging process, minimizing the time to open the next log file if the current one is full 32 +* resolving the stability problem when the SD card is full 33 + 34 += v2.7.1 = 35 + 36 +[[BMS_Main_3_v2.7.1.bin>>FileManager.BMS_Main_3_v2\.7\.1\.bin]] 37 + 38 +== Improvements == 39 + 40 +* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V 41 +* ability to generate the "Logic count error" also during BMS initialization (scanning of BMS Logic devices); new parameters for setting delays before/after generating/clearing the error (see the "Protections - Logic count" section) 42 +* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address 43 + 44 +== Fixes == 45 + 46 +* small fixes in dynamic current maps 47 + 6 6 = v2.7.0 = 7 7 8 8 [[BMS_Main_3_v2.7.0.bin>>FileManager.BMS_Main_3_v2\.7\.0\.bin]]