Changes for page BMS Main 3

Last modified by Admin on 2025/10/03 09:00

From version 19.1
edited by Admin
on 2025/10/03 09:00
Change comment: There is no comment for this version
To version 13.1
edited by Admin
on 2025/03/20 05:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,102 +3,6 @@
3 3  BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
4 4  )))
5 5  
6 -= v2.7.0 =
7 -
8 -[[BMS_Main_3_v2.7.0.bin>>FileManager.BMS_Main_3_v2\.7\.0\.bin]]
9 -
10 -== Features ==
11 -
12 -* new algorithm for detecting loss of wire connection to battery cells
13 -* new protection for detecting battery cell imbalance (see the "Protections - Cell imbalance" section)
14 -* new "Main X offline" error indicating loss of connection with the BMS Main X device
15 -
16 -== Improvements ==
17 -
18 -* new flag enabling fast current measurements (see the "Signals - Current sensor" section)
19 -* new parameters that control setting/clearing the "Ready to charge" and "Ready to discharge" signals based on the charge and/or discharge current limits (see the "Control - Charging status" and "Control - Discharging status" sections)
20 -* new parameters to ignore the specified errors when setting the critical error (see the "Protections - Critical error" section)
21 -* displaying HV calibration values for the service account (see the "Service - Calibration" section)
22 -
23 -= v2.6.0 =
24 -
25 -[[BMS_Main_3_v2.6.0.bin>>FileManager.BMS_Main_3_v2\.6\.0\.bin]]
26 -
27 -== Features ==
28 -
29 -* support for sending battery state and events via MQTT protocol via Wi-Fi or cellular network (see the "Service - MQTT" section)
30 -
31 -== Improvements ==
32 -
33 -* support for secure (TLS) connections in BMS GSM v1 and v2 drivers
34 -
35 -== Fixes ==
36 -
37 -* synchronization of the precharge procedure with the charge/discharge algorithms, so that precharge is stopped if charging and discharging are prohibited
38 -
39 -= v2.5.0 =
40 -
41 -[[BMS_Main_3_v2.5.0.bin>>FileManager.BMS_Main_3_v2\.5\.0\.bin]]
42 -
43 -== Features ==
44 -
45 -* new protection checking that the sum of cell voltages is equal to the voltage before contactors (the "High voltage 1" value). If this is not the case, the error "Battery voltage mismatch" is generated (see the "Protections - Battery voltage" section)
46 -* new protection checking that the number of cell temperature sensors is equal to the specified value. If this is not the case, the "T-sensor count error" is generated (see the "Protections - Temperature sensor count" section)
47 -
48 -== Improvements ==
49 -
50 -* new parameters that configure delays before and after the "Logic offline" error is generated (see the "Protections - Logic offline" section)
51 -* new CLI command "find-log" which finds a log file containing a specified timestamp
52 -
53 -== Fixes ==
54 -
55 -* resolving the issue of rebooting the device if formatting the SD card is activated
56 -
57 -= v2.4.0 =
58 -
59 -[[BMS_Main_3_v2.4.0.bin>>FileManager.BMS_Main_3_v2\.4\.0\.bin]]
60 -
61 -== Features ==
62 -
63 -* ability to communicate with BMS Logic devices via CLI (used in service-scripts, for example, to update BMS Logic firmware)
64 -* ability to calibrate high voltage measuring means, available starting with the service account (see the "Service - Calibration" section)
65 -
66 -== Improvements ==
67 -
68 -* new type of temperature sensors: NTC 10k B25/50=3380K (see the "Signals - Temperature sensors" section)
69 -
70 -= v2.3.0 =
71 -
72 -[[BMS_Main_3_v2.3.0.bin>>FileManager.BMS_Main_3_v2\.3\.0\.bin]]
73 -
74 -== Improvements ==
75 -
76 -* new parameter for setting the type of temperature sensors 1 and 2 connected to the device (sensors connected to BMS Logic devices and to BMS Main 3 device may differ; see the "Signals - Temperature sensors" section)
77 -* new flags that force only positive and negative currents to be used to determine open circuit voltages to control the "Ready to charge" and "Ready to discharge" signals respectively
78 -* new parameter setting a delay before measuring battery current during precharge (see the "Control - Precharge" section)
79 -* new flag to keep the precharging contactor closed until the precharging process is finished (in this case the "Precharge error" will not occur except for the one caused by high power; see the "Control - Precharge" section)
80 -* new flag to prevent the "HYG offline" error from occurring if the "Charger connected" signal is set (see the "External equipment - Trucks and Vehicles - HYG Class I-III truck" section)
81 -* new flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged (see the "External equipment - Trucks and Vehicles - HYG Class I-III truck" section)
82 -* new flag that controls whether to wait for confirmation from the Combilift truck or not, to allow the battery to be charged (see the "External equipment - Trucks and Vehicles - Combilift truck" section)
83 -* 30 second delay when remounting SD card after detecting mount error
84 -* new counter of retry attempts showing the communication problems with BMS Logic devices (see the "Battery" section)
85 -
86 -== Fixes ==
87 -
88 -* increased number of retries when sending commands to BMS Logic devices, which reduces the number of false offline event detections
89 -
90 -= v2.2.3 =
91 -
92 -[[BMS_Main_3_v2.2.3.bin>>FileManager.BMS_Main_3_v2\.2\.3\.bin]]
93 -
94 -== Improvements ==
95 -
96 -* new parameter for setting the type of network to which the BMS GSM communication module connects (see the "Connectivity - Cellular" section)
97 -
98 -== Fixes ==
99 -
100 -* resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells)
101 -
102 102  = v2.2.2 =
103 103  
104 104  [[BMS_Main_3_v2.2.2.bin>>FileManager.BMS_Main_3_v2\.2\.2\.bin]]