Changes for page BMS Main 3
Last modified by Admin on 2025/12/10 16:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,6 +3,53 @@ 3 3 BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v2.7.1 = 7 + 8 +[[BMS_Main_3_v2.7.1.bin>>FileManager.BMS_Main_3_v2\.7\.1\.bin]] 9 + 10 +== Improvements == 11 + 12 +* turning on power switches with a delay of 1 second after reaching the supply voltage of 9V 13 +* ability to generate the "Logic count error" also during BMS initialization (scanning of BMS Logic devices); new parameters for setting delays before/after generating/clearing the error (see the "Protections - Logic count" section) 14 +* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN1 (ext) settings; all CAN2 (int) settings; all RS-485-1 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address 15 + 16 +== Fixes == 17 + 18 +* small fixes in dynamic current maps 19 + 20 += v2.7.0 = 21 + 22 +[[BMS_Main_3_v2.7.0.bin>>FileManager.BMS_Main_3_v2\.7\.0\.bin]] 23 + 24 +== Features == 25 + 26 +* new algorithm for detecting loss of wire connection to battery cells 27 +* new protection for detecting battery cell imbalance (see the "Protections - Cell imbalance" section) 28 +* new "Main X offline" error indicating loss of connection with the BMS Main X device 29 + 30 +== Improvements == 31 + 32 +* new flag enabling fast current measurements (see the "Signals - Current sensor" section) 33 +* new parameters that control setting/clearing the "Ready to charge" and "Ready to discharge" signals based on the charge and/or discharge current limits (see the "Control - Charging status" and "Control - Discharging status" sections) 34 +* new parameters to ignore the specified errors when setting the critical error (see the "Protections - Critical error" section) 35 +* displaying HV calibration values for the service account (see the "Service - Calibration" section) 36 + 37 += v2.6.0 = 38 + 39 +[[BMS_Main_3_v2.6.0.bin>>FileManager.BMS_Main_3_v2\.6\.0\.bin]] 40 + 41 +== Features == 42 + 43 +* support for sending battery state and events via MQTT protocol via Wi-Fi or cellular network (see the "Service - MQTT" section) 44 + 45 +== Improvements == 46 + 47 +* support for secure (TLS) connections in BMS GSM v1 and v2 drivers 48 + 49 +== Fixes == 50 + 51 +* synchronization of the precharge procedure with the charge/discharge algorithms, so that precharge is stopped if charging and discharging are prohibited 52 + 6 6 = v2.5.0 = 7 7 8 8 [[BMS_Main_3_v2.5.0.bin>>FileManager.BMS_Main_3_v2\.5\.0\.bin]]