Changes for page BMS Main 3
Last modified by Admin on 2025/07/17 02:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,6 +3,24 @@ 3 3 BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v2.5.0 = 7 + 8 +[[BMS_Main_3_v2.5.0.bin>>FileManager.BMS_Main_3_v2\.5\.0\.bin]] 9 + 10 +== Features == 11 + 12 +* new protection checking that the sum of cell voltages is equal to the voltage before contactors (the "High voltage 1" value). If this is not the case, the error "Battery voltage mismatch" is generated (see the "Protections - Battery voltage" section) 13 +* new protection checking that the number of cell temperature sensors is equal to the specified value. If this is not the case, the "T-sensor count error" is generated (see the "Protections - Temperature sensor count" section) 14 + 15 +== Improvements == 16 + 17 +* new parameters that configure delays before and after the "Logic offline" error is generated (see the "Protections - Logic offline" section) 18 +* new CLI command "find-log" which finds a log file containing a specified timestamp 19 + 20 +== Fixes == 21 + 22 +* resolving the issue of rebooting the device if formatting the SD card is activated 23 + 6 6 = v2.4.0 = 7 7 8 8 [[BMS_Main_3_v2.4.0.bin>>FileManager.BMS_Main_3_v2\.4\.0\.bin]]