Changes for page BMS Main 3
Last modified by Admin on 2025/04/15 09:56
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Tags
-
... ... @@ -1,1 +1,0 @@ 1 -BMS Main 3 - Content
-
... ... @@ -1,77 +1,7 @@ 1 -(% class="box infomessage" %) 2 -((( 3 -BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 -))) 1 += 2.1.1 = 5 5 6 -= v2.2.3 = 7 - 8 -[[BMS_Main_3_v2.2.3.bin>>FileManager.BMS_Main_3_v2\.2\.3\.bin]] 9 - 10 10 == Improvements == 11 11 12 -* new parameter for setting the type of network to which the BMS GSM communication module connects (see the "Connectivity - Cellular" section) 13 - 14 -== Fixes == 15 - 16 -* resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells) 17 - 18 -= v2.2.2 = 19 - 20 -[[BMS_Main_3_v2.2.2.bin>>FileManager.BMS_Main_3_v2\.2\.2\.bin]] 21 - 22 -== Improvements == 23 - 24 -* increasing the accuracy of resistance calculations 25 -* new parameters for battery manufacturers: manufacturer name, hardware ID, software ID, configuration description, production date (see the "Service - User settings" section) 26 - 27 -= v2.2.1 = 28 - 29 -[[BMS_Main_3_v2.2.1.bin>>FileManager.BMS_Main_3_v2\.2\.1\.bin]] 30 - 31 -== Improvements == 32 - 33 -* increasing the smoothness of changing the current limit values 34 -* ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) 35 -* extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.) 36 - 37 -== Fixes == 38 - 39 -* resolving the issue of working with the Fronius charger over the CAN1 interface 40 -* small internal fixes 41 - 42 -= v2.2.0 = 43 - 44 -[[BMS_Main_3_v2.2.0.bin>>FileManager.BMS_Main_3_v2\.2\.0\.bin]] 45 - 46 -== Features == 47 - 48 -* support for the HYG Global CAN protocol version 2 (June 13, 2024) 49 -* calculation of regenerated energy 50 -* calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section 51 -* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 52 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section) 53 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section) 54 -* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section 55 -* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively 56 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections) 57 -* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 58 -* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 59 - 60 -== Improvements == 61 - 62 -* ability to configure and monitor the device via the CAN1 (ext) bus 63 -* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 64 - 65 -== Fixes == 66 - 67 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 68 - 69 -= v2.1.1 = 70 - 71 -[[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]] 72 - 73 -== Improvements == 74 - 75 75 * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Control - Cell balancing" section) 76 76 77 77 == Fixes == ... ... @@ -79,20 +79,4 @@ 79 79 * resolving the possible problem of saving device parameters 80 80 * resolving the problem of writing the device's working time to a non-volatile memory very often 81 81 82 -= v2.1.0 = 83 - 84 -[[BMS_Main_3_v2.1.0.bin>>FileManager.BMS_Main_3_v2\.1\.0\.bin]] 85 - 86 -== Features == 87 - 88 -* new algorithms in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithms are preferred in the battery systems with one contactor. 89 -* selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Charge/Discharge", "Control - Discharge (AUX)", "Control - Heater", "Control - Cooler", "Protections - General error", "Control - Charging status", "Control - Discharging status" sections) 90 -* new "Current limit error" which is set if the battery current exceeds the charging or discharging current limits (see the "Protections - Charge current limit" and "Protections - Discharge current limit" sections) 91 -* new parameter to select the method of calculating the battery voltage: sum the cell voltages or use the measured voltage before contactors (see the "Control - Common settings" section) 92 -* clearing the Discharging (AUX) signal if the cell voltage is too low (see the "Control - Discharge (AUX)" section) 93 -* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input discrete signals - Assignments" section) 94 -* new assignment "External 1" for the discrete outputs and power switches (see the "Signals - Output discrete signals - Assignments" and "Signals - Power switches - Assignments" sections). The "External 1" output is directly controlled by the "Close External 1" command. 95 - 96 -== Improvements == 97 - 98 -* rearrangements in the settings sections, which are made to simplify the setup process 12 +2