Changes for page BMS Main 3
Last modified by Admin on 2025/02/18 14:57
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Tags
-
... ... @@ -1,1 +1,0 @@ 1 -BMS Main 3 - Content
-
... ... @@ -1,52 +1,5 @@ 1 -(% class="box infomessage" %) 2 -((( 3 -BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]]. 4 -))) 1 += 2.1.1 = 5 5 6 -= v2.2.1 = 7 - 8 -... 9 - 10 -== Improvements == 11 - 12 -* increasing the smoothness of changing the current limit values 13 -* ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) 14 -* extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.) 15 - 16 -== Fixes == 17 - 18 -* resolving the issue of working with the Fronius charger over the CAN1 interface 19 -* small internal fixes 20 - 21 -= v2.2.0 = 22 - 23 -[[BMS_Main_3_v2.2.0.bin>>FileManager.BMS_Main_3_v2\.2\.0\.bin]] 24 - 25 -== Features == 26 - 27 -* support for the HYG Global CAN protocol version 2 (June 13, 2024) 28 -* calculation of regenerated energy 29 -* calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section 30 -* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 31 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section) 32 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section) 33 -* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section 34 -* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively 35 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections) 36 -* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 37 -* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 38 - 39 -== Improvements == 40 - 41 -* ability to configure and monitor the device via the CAN1 (ext) bus 42 -* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 43 - 44 -== Fixes == 45 - 46 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 47 - 48 -= v2.1.1 = 49 - 50 50 [[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]] 51 51 52 52 == Improvements == ... ... @@ -58,7 +58,7 @@ 58 58 * resolving the possible problem of saving device parameters 59 59 * resolving the problem of writing the device's working time to a non-volatile memory very often 60 60 61 -= v2.1.0 =14 += 2.1.0 = 62 62 63 63 [[BMS_Main_3_v2.1.0.bin>>FileManager.BMS_Main_3_v2\.1\.0\.bin]] 64 64