... ... @@ -1,0 +1,1 @@
1 +BMS Main 3
Content
... ... @@ -1,7 +1,41 @@
1 -= 2.1.1 =
1 +(% class="box infomessage" %)
2 +(((
3 +BMS Main 3 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 3.5\. Firmware update.WebHome]].
4 +)))
2 2  
6 += v2.2.0 =
7 +
8 +[[BMS_Main_3_v2.2.0.bin>>FileManager.BMS_Main_3_v2\.2\.0\.bin]]
9 +
10 +== Features ==
11 +
12 +* support for the HYG Global CAN protocol version 2 (June 13, 2024)
13 +* calculation of regenerated energy
14 +* calculation of new lifetime parameters: average temperature, average charge/discharge currents, etc. See the counters in the "Service - Counters" section
15 +* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section
16 +* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section)
17 +* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section)
18 +* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section
19 +* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
20 +* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections)
21 +* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section)
22 +* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section)
23 +
3 3  == Improvements ==
4 4  
26 +* ability to configure and monitor the device via the CAN1 (ext) bus
27 +* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section
28 +
29 +== Fixes ==
30 +
31 +* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
32 +
33 += v2.1.1 =
34 +
35 +[[BMS_Main_3_v2.1.1.bin>>FileManager.BMS_Main_3_v2\.1\.1\.bin]]
36 +
37 +== Improvements ==
38 +
5 5  * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Control - Cell balancing" section)
6 6  
7 7  == Fixes ==
... ... @@ -9,4 +9,20 @@
9 9  * resolving the possible problem of saving device parameters
10 10  * resolving the problem of writing the device's working time to a non-volatile memory very often
11 11  
12 -2
46 += v2.1.0 =
47 +
48 +[[BMS_Main_3_v2.1.0.bin>>FileManager.BMS_Main_3_v2\.1\.0\.bin]]
49 +
50 +== Features ==
51 +
52 +* new algorithms in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithms are preferred in the battery systems with one contactor.
53 +* selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Charge/Discharge", "Control - Discharge (AUX)", "Control - Heater", "Control - Cooler", "Protections - General error", "Control - Charging status", "Control - Discharging status" sections)
54 +* new "Current limit error" which is set if the battery current exceeds the charging or discharging current limits (see the "Protections - Charge current limit" and "Protections - Discharge current limit" sections)
55 +* new parameter to select the method of calculating the battery voltage: sum the cell voltages or use the measured voltage before contactors (see the "Control - Common settings" section)
56 +* clearing the Discharging (AUX) signal if the cell voltage is too low (see the "Control - Discharge (AUX)" section)
57 +* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input discrete signals - Assignments" section)
58 +* new assignment "External 1" for the discrete outputs and power switches (see the "Signals - Output discrete signals - Assignments" and "Signals - Power switches - Assignments" sections). The "External 1" output is directly controlled by the "Close External 1" command.
59 +
60 +== Improvements ==
61 +
62 +* rearrangements in the settings sections, which are made to simplify the setup process