12.1 | 6 | = v1.70.1 = |
7 | |||
8 | [[BMS_Main_2.1_v1.70.1.srec>>FileManager.BMS_Main_2\.1_v1\.70\.1\.srec]] | ||
9 | |||
10 | == Improvements == | ||
11 | |||
12 | * new assignments "Low SOC" and "High charging current" for relays | ||
13 | |||
14 | == Fixes == | ||
15 | |||
16 | * resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells) | ||
17 | |||
![]() |
10.1 | 18 | = v1.70.0 = |
19 | |||
20 | [[BMS_Main_2.1_v1.70.0.srec>>FileManager.BMS_Main_2\.1_v1\.70\.0\.srec]] | ||
21 | |||
22 | == Features == | ||
23 | |||
![]() |
11.1 | 24 | * new parameters allowing to set different delays for battery discharge mode to detect the overcurrent error (see the "Protections - Overcurrent protection" section) |
![]() |
10.1 | 25 | * new flag that sets whether the BMS should wait for confirmation messages from the Combilift truck to start charging or not (see the "External equipment - Combilift truck" section) |
26 | |||
27 | == Fixes == | ||
28 | |||
29 | * optimization of the logging process, minimizing the time to open the next log file if the current one is full | ||
30 | |||
![]() |
9.1 | 31 | = v1.69.1 = |
32 | |||
33 | [[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]] | ||
34 | |||
35 | == Fixes == | ||
36 | |||
37 | * check the HYG and Combilift confirmation flags only if the truck offline error is not set | ||
38 | * small internal fixes | ||
39 | |||
![]() |
8.1 | 40 | = v1.69.0 = |
41 | |||
42 | [[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]] | ||
43 | |||
44 | == Features == | ||
45 | |||
46 | * new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section) | ||
47 | * new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section) | ||
48 | * new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section) | ||
49 | * new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section | ||
50 | * new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section) | ||
51 | * new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command | ||
52 | * new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section) | ||
53 | * new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command. | ||
54 | * new "Precharge error" flag that is set when precharging cannot be completed | ||
55 | * new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively | ||
56 | * ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections) | ||
57 | |||
58 | == Improvements == | ||
59 | |||
60 | * ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error") | ||
61 | * explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section) | ||
62 | * improving resistance calculation | ||
63 | |||
64 | == Fixes == | ||
65 | |||
66 | * resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal | ||
67 | * using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals | ||
68 | |||
![]() |
6.1 | 69 | = v1.68.0 = |
70 | |||
71 | [[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]] | ||
72 | |||
73 | == Features == | ||
74 | |||
75 | - support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)") | ||
76 | |||
![]() |
3.1 | 77 | = v1.67.0 = |
78 | |||
79 | [[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]] | ||
80 | |||
81 | == Features == | ||
82 | |||
83 | * new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay | ||
84 | |||
85 | == Improvements == | ||
86 | |||
87 | * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section) | ||
88 | |||
89 | = v1.66.1 = | ||
90 | |||
91 | [[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]] | ||
92 | |||
93 | == Improvements == | ||
94 | |||
95 | * closing all TCP connections over Ethernet if the interface link is down | ||
96 | |||
![]() |
2.1 | 97 | = v1.66.0 = |
![]() |
1.2 | 98 | |
99 | [[BMS_Main_2.1_v1.66.0.srec>>FileManager.BMS_Main_2\.1_v1\.66\.0\.srec]] | ||
100 | |||
![]() |
2.1 | 101 | == Features == |
102 | |||
103 | * support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device") | ||
104 | |||
105 | == Improvements == | ||
106 | |||
107 | * new parameters for switching off the Discharging (AUX) relay when the cell voltage is too low (see the "Cells - Discharging (AUX) control" section) |