Wiki source code of BMS Main 2.1

Version 9.1 by Admin on 2025/02/19 10:47

Show last authors
1 (% class="box infomessage" %)
2 (((
3 BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]].
4 )))
5
6 = v1.69.1 =
7
8 [[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]]
9
10 == Fixes ==
11
12 * check the HYG and Combilift confirmation flags only if the truck offline error is not set
13 * small internal fixes
14
15 = v1.69.0 =
16
17 [[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]]
18
19 == Features ==
20
21 * new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section)
22 * new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section)
23 * new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section)
24 * new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section
25 * new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section)
26 * new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command
27 * new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section)
28 * new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command.
29 * new "Precharge error" flag that is set when precharging cannot be completed
30 * new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
31 * ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections)
32
33 == Improvements ==
34
35 * ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error")
36 * explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section)
37 * improving resistance calculation
38
39 == Fixes ==
40
41 * resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal
42 * using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
43
44 = v1.68.0 =
45
46 [[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]]
47
48 == Features ==
49
50 - support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)")
51
52 = v1.67.0 =
53
54 [[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]]
55
56 == Features ==
57
58 * new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay
59
60 == Improvements ==
61
62 * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section)
63
64 = v1.66.1 =
65
66 [[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]]
67
68 == Improvements ==
69
70 * closing all TCP connections over Ethernet if the interface link is down
71
72 = v1.66.0 =
73
74 [[BMS_Main_2.1_v1.66.0.srec>>FileManager.BMS_Main_2\.1_v1\.66\.0\.srec]]
75
76 == Features ==
77
78 * support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device")
79