Wiki source code of BMS Main 2.1

Version 8.1 by Admin on 2025/01/21 08:01

Hide last authors
Admin 7.1 1 (% class="box infomessage" %)
2 (((
Admin 5.1 3 BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]].
Admin 7.1 4 )))
Admin 4.1 5
Admin 8.1 6 = v1.69.0 =
7
8 [[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]]
9
10 == Features ==
11
12 * new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section)
13 * new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section)
14 * new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section)
15 * new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section
16 * new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section)
17 * new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command
18 * new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section)
19 * new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command.
20 * new "Precharge error" flag that is set when precharging cannot be completed
21 * new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
22 * ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections)
23
24 == Improvements ==
25
26 * ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error")
27 * explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section)
28 * improving resistance calculation
29
30 == Fixes ==
31
32 * resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal
33 * using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
34
Admin 6.1 35 = v1.68.0 =
36
37 [[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]]
38
39 == Features ==
40
41 - support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)")
42
Admin 3.1 43 = v1.67.0 =
44
45 [[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]]
46
47 == Features ==
48
49 * new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay
50
51 == Improvements ==
52
53 * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section)
54
55 = v1.66.1 =
56
57 [[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]]
58
59 == Improvements ==
60
61 * closing all TCP connections over Ethernet if the interface link is down
62
Admin 2.1 63 = v1.66.0 =
Admin 1.2 64
65 [[BMS_Main_2.1_v1.66.0.srec>>FileManager.BMS_Main_2\.1_v1\.66\.0\.srec]]
66
Admin 2.1 67 == Features ==
68
69 * support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device")
70
71 == Improvements ==
72
73 * new parameters for switching off the Discharging (AUX) relay when the cell voltage is too low (see the "Cells - Discharging (AUX) control" section)