BMS Main 2.1

Version 7.1 by Admin on 2024/12/25 14:05

BMS Main 2.1 firmware update procedure is described here.

v1.68.0

BMS_Main_2.1_v1.68.0.srec 

Features

- support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)")

v1.67.0

BMS_Main_2.1_v1.67.0.srec 

Features

  • new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay

Improvements

  • new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section)

v1.66.1

BMS_Main_2.1_v1.66.1.srec 

Improvements

  • closing all TCP connections over Ethernet if the interface link is down

v1.66.0

BMS_Main_2.1_v1.66.0.srec 

Features

  • support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device")

Improvements

  • new parameters for switching off the Discharging (AUX) relay when the cell voltage is too low (see the "Cells - Discharging (AUX) control" section)