Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | (% class="wikigeneratedid" %) | ||
| 2 | BMS Main 2.1 firmware upgrade procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]. | ||
| 3 | |||
| 4 | = v1.67.0 = | ||
| 5 | |||
| 6 | [[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]] | ||
| 7 | |||
| 8 | == Features == | ||
| 9 | |||
| 10 | * new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay | ||
| 11 | |||
| 12 | == Improvements == | ||
| 13 | |||
| 14 | * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section) | ||
| 15 | |||
| 16 | = v1.66.1 = | ||
| 17 | |||
| 18 | [[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]] | ||
| 19 | |||
| 20 | == Improvements == | ||
| 21 | |||
| 22 | * closing all TCP connections over Ethernet if the interface link is down | ||
| 23 | |||
| 24 | = v1.66.0 = | ||
| 25 | |||
| 26 | [[BMS_Main_2.1_v1.66.0.srec>>FileManager.BMS_Main_2\.1_v1\.66\.0\.srec]] | ||
| 27 | |||
| 28 | == Features == | ||
| 29 | |||
| 30 | * support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device") | ||
| 31 | |||
| 32 | == Improvements == | ||
| 33 | |||
| 34 | * new parameters for switching off the Discharging (AUX) relay when the cell voltage is too low (see the "Cells - Discharging (AUX) control" section) |