v1.67.0
BMS_Main_2.1_v1.67.0.srec
Features
- new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay
Improvements
- new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section)
v1.66.1
BMS_Main_2.1_v1.66.1.srec
Improvements
- closing all TCP connections over Ethernet if the interface link is down
v1.66.0
BMS_Main_2.1_v1.66.0.srec
Features
- support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device")
Improvements
- new parameters for switching off the Discharging (AUX) relay when the cell voltage is too low (see the "Cells - Discharging (AUX) control" section)